Mutual localization of electrode pairs in a 4-electrode measuring system
نویسندگان
چکیده
منابع مشابه
Electrode System Influence on Biphasic
Background. Several clinical studies have demonstrated a general superiority of biphasic waveform defibrillation compared with monophasic waveform defibrillation using epicardial lead systems. To test the breadth of utility of biphasic waveforms in humans, a prospective, randomized evaluation of defibrillation efficacy of monophasic and single capacitor biphasic waveform pulses was performed fo...
متن کاملHigh Resolution In-Vivo Electrode Localization Using Microfocal X-Rays
Neuroscientists lack the ability to perform in-vivo electrode localization with high accuracy, especially in deep brain structures. The design, implementation and testing of a microfocal x-ray stereo system that offers an efficient, accurate, and relatively low-cost solution this localization problem is presented. The results indicate the ability to localize a targets to within ~50 microns, in ...
متن کاملStereotactic atlas-based depth electrode localization in the human amygdala.
BACKGROUND The efficacy of stereotactic neurosurgery procedures is critically dependent on the accuracy of the device placement procedure. The first step in this process involves correctly identifying the target location in three-dimensional brain space. In some clinical applications, this targeting process cannot be accomplished using MRI images of gross anatomical structures alone. The amygda...
متن کاملAutomatic localization of EEG electrode markers within 3D MR data.
The electrical activity of the brain can be monitored using ElectroEncephaloGraphy (EEG). From the positions of the EEG electrodes, it is possible to localize focal brain activity. Thereby, the accuracy of the localization strongly depends on the accuracy with which the positions of the electrodes can be determined. In this work, we present an automatic, simple, and accurate scheme that detects...
متن کاملLocalization of dense intracranial electrode arrays using magnetic resonance imaging
Intracranial electrode arrays are routinely used in the pre-surgical evaluation of patients with medically refractory epilepsy, and recordings from these electrodes have been increasingly employed in human cognitive neurophysiology due to their high spatial and temporal resolution. For both researchers and clinicians, it is critical to localize electrode positions relative to the subject-specif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2010
ISSN: 1742-6596
DOI: 10.1088/1742-6596/224/1/012074