Mycobacterium abscessus causing native valve endocarditis due to peripherally inserted central catheter line

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Native valve endocarditis due to Enterococcus hirae.

Enterococcus hirae is a rare isolate in clinical specimens. We describe a case of native aortic-valve endocarditis that was caused by Enterococcus hirae in a 72-year-old man. This is the first reported case of endocarditis due to this organism.

متن کامل

Pericardial Effusion in an Extreme Low Birth Weight Neonate with Peripherally Inserted Central Catheter

Background: Pericardial effusion and cardiac tamponade are the rare complications of peripherally inserted central catheters (PICC insertion) in extreme low birth weight infants. In this regard, paying attention to these complications is of utmost importance, because they can result in infant death. Case report: The case of our infant is a sa...

متن کامل

Complications of Peripherally Inserted Central Catheter (picc) in Neonates

Peripherally Inserted Central Catheter (PICC) is an intravenous device whose distal end is located in the vena cava, becoming a central venous catheter; despite its benefits, can aggregate risk to the neonates. Aimed to characterize and analyze the PICC complications in neonates. An exploratory, descriptive, documentary and retrospective research with a quantitative approach; ethical principles...

متن کامل

Prosthetic valve endocarditis due to Mycobacterium chelonei.

Starr-Edwards mitral and aortic prosthetic valves served as nidi for endocarditis due to M chelonei. Cultural, physiologic, lipid chromatographic, and serologic studies identified the organism as M chelonei (abscessus).

متن کامل

Peripherally inserted central catheter placement using the Sonic Flashlight.

The Sonic Flashlight is an ultrasound (US) device that projects real-time US images into patients with use of a semireflective/transparent mirror. The present study evaluated the feasibility of use of the Sonic Flashlight for clinical peripherally inserted central catheter placements, originally with the mirror located inside a sterile cover (n = 15), then with the mirror outside (n = 11). Succ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Tuberculosis and Other Mycobacterial Diseases

سال: 2017

ISSN: 2405-5794

DOI: 10.1016/j.jctube.2017.09.001