Myocardial blood flow quantitation with the SPECT technique: Is it ready to be a substitute for PET myocardial blood flow quantitation?

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absolute quantitation of myocardial blood flow in human subjects with or without myocardial ischemia using dynamic flurpiridaz F 18 PET.

UNLABELLED Absolute quantitation of myocardial blood flow (MBF) by PET is an established method of analyzing coronary artery disease (CAD) but subject to the various shortcomings of available radiotracers. Flurpiridaz F 18 is a novel PET radiotracer that exhibits properties of an ideal tracer. METHODS A new absolute perfusion quantitation method with flurpiridaz was developed, taking advantag...

متن کامل

Quantitative Assessment of Regional Myocardial Blood Flow with Clinical SPECT

This article gives an overview of essential requirements and limitations in the quantitative assessment of regional myocardial perfusion or regional myocardial blood flow (rMBF) using existing clinical SPECT systems in clinical settings. One major requirement is the need for acquiring complete projection data without truncation. Attenuation and scatter are then prerequisites to reproduce quanti...

متن کامل

Myocardial Blood Flow

We examined the ability of individual regions of the canine left ventricle to increase blood flow relative to baseline rates of perfusion. Regional coronary flow was measured by injecting radioactive microspheres over 90 seconds in seven anesthetized mongrel dogs. Preliminary experiments demonstrated a correlation between the regional distributions of blood flow during asphyxia and pharmacologi...

متن کامل

Myocardial Blood Flow

Coronary sinus flow (CSF) was measured in seven patients with normal coronary arteries (group A) during intracoronary injections of 6 ml arterial blood, 6 ml blood from the coronary sinus, 3 and 6 ml isotonic saline, 3 and 6 ml hypertonic glucose, and 6 ml of a contrast agent (sodium metrizoate). In 10 patients with coronary artery disease (group B), CSF was measured after administration of 6 m...

متن کامل

Myocardial Blood Flow

Current methods of measuring myocardial blood flow using 133xenon have failed to separate normals from patients with ischemic heart disease at rest. In the present study such a separation was attempted by utilizing pacing-induced tachycardia (PIT) to stress the myocardium. 133Xenon was injected into the left coronary artery to measure blood flow in 27 patients at rest and during pacing-induced ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Nuclear Cardiology

سال: 2021

ISSN: 1071-3581,1532-6551

DOI: 10.1007/s12350-021-02697-5