Nanoplasma Formation by High Intensity Hard X-rays
نویسندگان
چکیده
منابع مشابه
Nanoplasma Formation by High Intensity Hard X-rays
Using electron spectroscopy, we have investigated nanoplasma formation from noble gas clusters exposed to high-intensity hard-x-ray pulses at ~5 keV. Our experiment was carried out at the SPring-8 Angstrom Compact free electron LAser (SACLA) facility in Japan. Dedicated theoretical simulations were performed with the molecular dynamics tool XMDYN. We found that in this unprecedented wavelength ...
متن کاملBlazars in hard X–rays
Although blazars are thought to emit most of their luminosity in the γ–ray band, there are subclasses of them very prominent in hard X–rays. These are the best candidates to be studied by Simbol–X. They are at the extremes of the blazar sequence, having very small or very high jet powers. The former are the class of TeV emitting BL Lacs, whose synchrotron emission often peaks at tens of keV or ...
متن کاملFormation of optical images by X-rays.
for double passage of the rays. A change of focusing is not necessary. Prism rotation and change of focus are always effected automatically. The apparatus can be used for the range of approximately 10,000 to 3700A. The resolving power for single passage of the rays is approximately 5600 at 10,OOOA; for double passage of the rays, 250,000 at 3700A. The "G 50" spectrograph was designed in 1939 an...
متن کاملNanometer focusing of hard x rays by phase zone plates
Focusing of 8 keV x rays to a spot size of 150 and 90 nm full width at half maximum have been demonstrated at the firstand third-order foci, respectively, of a phase zone plate ~PZP!. The PZP has a numerical aperture of 1.5 mrad and focusing efficiency of 13% for 8 keV x rays. A flux density gain of 121 000 was obtained at the first-order focus. In this article, the fabrication of the PZP and i...
متن کاملSIMBOL–X a formation flying mission for hard X-rays astrophysics
SIMBOL-X is a hard X-ray mission, operating in the ~ 0.5–70 keV range, which is proposed by a consortium of European laboratories in response to the 2004 call for ideas of CNES for a scientific mission to be flown on a formation flying demonstrator. Relying on two spacecrafts in a formation flying configuration, SIMBOL–X uses for the first time a ~ 30 m focal length X–ray mirror to focus X–rays...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2015
ISSN: 2045-2322
DOI: 10.1038/srep10977