Nanosecond Light Source, XP‐20
نویسندگان
چکیده
منابع مشابه
A Laser Triggered Synchronizable, Sub-Nanosecond Pulsed Electron Source
A laser excited, sub-nanosecond, pulsed electron beam system is described. The system consists of a high voltage pulser and a coaxial triggered spark gap. The liquid spark gap discharges into a pulse forming line designed to produce and maintain a flat voltage pulse of 1ns duration on the cathode of a photodiode. A synchronized laser is used to illuminate the photo-cathode to produce an electro...
متن کاملNanosecond transient electroluminescence from polymer light-emitting diodes
The transient electroluminescence from polymer light-emitting diodes is reported. When the devices are mounted on a microstrip transmission line, the temporal response is limited by the electrode geometry, with rise and fall times below 50 ns. With low duty-cycle pulses (0.5%) the electroluminescence intensity remains proportional to the current at values up to 10 A/cm2, two orders of magnitude...
متن کاملEfficacy of the intense pulsed light source on unwanted hairs
Background: The need for a rapid, non-invasive method for unwanted hair removal has led to the development of various light sources for this purpose. Objective: To evaluate the efficacy of Intense Pulsed Light Source (IPLS) on unwanted hairs. Patients and Methods: In this open, uncontrolled clinical trial, 77 different anatomical areas in 34 referred patients to “Novin Didegan Clinic” in Tehran...
متن کاملbeamlines for iranian light source facility
this paper describes day-one beamlines of the iranian light source facility and design concept of powder diffraction and spectromicroscopy beamlines as the most priorities of each synchrotron that cover the research requirements in the fields of physics, chemistry, nano-science, etc. for powder diffraction beamline energy range is 6-30 kev, resolution: 10-4, flux: 1012(ph/s/0.1%b.w.) and spot s...
متن کاملCanadian Light Source Update
The Canadian Light Source (CLS) storage ring has been operating routinely since commissioning was completed in the spring of 2004. Beam currents up to 230 mA have been achieved with the single superconducting RF cavity. With steady improvement beam lifetimes (1/e) of 14 hours at 200 mA and 0.5% coupling are now possible. In the last year the vertical tune was increased by 1 integer to produce a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 1967
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.1720680