Near-infrared multispectral photoacoustic microscopy using a graded-index fiber amplifier

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Near-infrared multispectral photoacoustic microscopy using a graded-index fiber amplifier

We demonstrate optical resolution photoacoustic microscopy (OR-PAM) of lipid-rich tissue using a multi-wavelength pulsed laser based on nonlinear fiber optics. 1047 nm laser pulses are converted to 1098, 1153, 1215, and 1270 nm pulses via stimulated Raman scattering in a graded-index multimode fiber. Multispectral PAM of a lipid phantom is demonstrated with our low-cost and simple technique.

متن کامل

Near-infrared optical-resolution photoacoustic microscopy.

Compared with visible light (380-700 nm), near-infrared light (700-1400 nm) undergoes weaker optical attenuation in biological tissue; thus, it can penetrate deeper. Herein, we demonstrate near-infrared optical-resolution photoacoustic microscopy (NIR-OR-PAM) with 1046 nm illumination. A penetration depth of 3.2 mm was achieved in chicken breast tissue ex vivo using optical fluence within the A...

متن کامل

Fiber-amplifier-enhanced photoacoustic spectroscopy with near-infrared tunable diode lasers.

A new approach to wavelength-modulation photoacoustic spectroscopy is reported, which incorporates diode lasers in the near infrared and optical fiber amplifiers to enhance sensitivity. We demonstrate the technique with ammonia detection, yielding a sensitivity limit less than 6 parts in 10(9), by interrogating a transition near 1532 nm with 500 mW of output power from the fiber amplifier, an o...

متن کامل

Real-time Near-infrared Virtual Intraoperative Surgical Photoacoustic Microscopy

We developed a near infrared (NIR) virtual intraoperative surgical photoacoustic microscopy (NIR-VISPAM) system that combines a conventional surgical microscope and an NIR light photoacoustic microscopy (PAM) system. NIR-VISPAM can simultaneously visualize PA B-scan images at a maximum display rate of 45 Hz and display enlarged microscopic images on a surgeon's view plane through the ocular len...

متن کامل

High-bandwidth, graded-index polymer optical fiber for near-infrared use.

We describe graded-index polymer optical fibers with high bandwidth (5.12 GHz for 100-m transmission) and low loss in the near-infrared region (56 and 115 dB/km at wavelengths of 688 and 773 nm, respectively) that we successfully obtained with a new interfacial-gel polymerization technique using an all-deuterated methyl methacrylate monomer and a partially fluorinated acrylate monomer. The nece...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Photoacoustics

سال: 2016

ISSN: 2213-5979

DOI: 10.1016/j.pacs.2016.08.002