Negative design inhibition of template‐assisted hemolysis
نویسندگان
چکیده
منابع مشابه
The Mechanism of the Inhibition of Hemolysis
The principal conclusion of this investigation is that the inhibitory effect of plasma or serum on hemolysis by saponin and lysins of the same type is similar in nature to the inhibitory effects of certain sugars and electrolytes, which again are similar to the acceleratory effects produced by indol, benzene, and other substances already studied. All these effects, both inhibitory and accelerat...
متن کاملDesign of Dual-Band Double Negative Metamaterials
A dual-band artificial magnetic material and then a dual-band double-negative metamaterial structure based on symmetric spiral resonators are presented. An approximate analytical model is used for the initial design of the proposed structures. The electromagnetic parameters of the proposed metamaterial structure retrieved using an advanced parameter retrieval method based on the causality princ...
متن کاملInhibition of protein crystallization by evolutionary negative design.
Why are proteins so hard to crystallize? We propose an 'evolutionary negative design' principle to explain this difficulty. Proteins have evolved to avoid crystallization because crystallization compromises the viability of the cell. Evolutionary negative design is supported by much evidence in the literature, including the effect of mutations on the crystallizability of a protein, the correlat...
متن کاملContemporary Oxygenator Design Relative to Hemolysis.
Hemolysis is a well-known phenomenon during cardiovascular surgery and generally attributed to cardiopulmonary bypass, particularly when using high-resistant oxygenators. This study aimed at investigating whether transoxygenator pressure drop can be considered an independent factor of hemolysis. Additionally, intraoxygenator blood distribution and shear stress were assessed. A low-resistant (LR...
متن کاملBlood Flow, Negative Pressure, and Hemolysis During Hemodialysis.
Blood flow, measured by an ultrasound flowmeter, and the extent of hemolysis were assessed during a single, routine dialysis in 100 patients. Before and after the hemodialysis session, blood was drawn for measurements of haptoglobin (HPT), hemoglobin (HGB), albumin (ALB), and lactate dehydrogenase (LDH). The average values were as follows: pump speed 510 mL/ min, real blood flow 422 mL/min, art...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The FASEB Journal
سال: 2010
ISSN: 0892-6638,1530-6860
DOI: 10.1096/fasebj.24.1_supplement.490.8