Network analyzer calibration using offset shorts
نویسندگان
چکیده
منابع مشابه
Calibration of a Metallic Access Network Analyzer
A calibration approach is proposed to compensate the systematic errors when the input reflection coefficient of a metallic access network cable is obtained using single port measurements from an access network analyzer. The analyzer is a versatile instrument and uses optimal cable matching and internal balancing to achieve maximum measurement resolution. The analyzer uses test-leads connected t...
متن کاملAn Optimal Vector-Network-Analyzer Calibration Algorithm
We present an iterative algorithm for calibrating vector network analyzers based on orthogonal distance regression. The algorithm features a robust, yet efficient, search algorithm, an error analysis that includes both random and systematic errors, a full covariance matrix relating calibration and measurement errors, 95% coverage factors, and an easy-to-use user interface that supports a wide v...
متن کاملOn-Wafer Vector Network Analyzer Calibration and Measurements
The representative VNA block diagram (see Figure 1) shows the key elements of the analyzer. The RF source at the top provides the device-under-test (DUT) stimulus. A forward/reverse switch directs the RF energy to either DUT port. The test set uses directional couplers or bridges to pick off the forward and reverse waves traveling to and from each port, and down-converts these signals to four I...
متن کاملAutomatic Robot Joint Offset Calibration
A contact-based calibration technique using a robot-mounted calibration probe, has been experimented with. The probe is to be implemented by utilizing a wrist-mounted force sensor. The technique is based on constraining the sampled robot joint poses to those where the probe end is in controlled contact with a planar surface. The paper illustrates how the technique may be used to achieve a joint...
متن کاملCalibration of a Quadrupole Gas Analyzer Using a Reference Gas*
A quadrupole gas analyzer system was calibrated for the gases H2, He, N2, 02, A, and Xe. The procedure involved first calibrating the system for argon, as the reference gas. This was done using conventional techniques. A mixture of the above gases was then introduced into the system to be calibrated. The system configuration was such that the ratio of the partial pressures of each of the test g...