Neutral particle beam intensity controller
نویسندگان
چکیده
منابع مشابه
Comparison of Laser and Neutral Particle Beam Discrimination
The relative ability of lasers and neutral particle beams (NPBs) to discriminate reentry vehicle (RV) and anti-satellite (ASAT) decoys is pivotal in assessing their relative worth as strategic defenses. This report evaluates their ability and assesses their relative contributions, concluding that NPBs can typically discriminate about 100 times as many objects as can lasers, and do so with signi...
متن کاملHyperthermal neutral beam etching
A pulsed beam of hyperthermal fluorine atoms with an average translational energy of 4.8 eV has been used to demonstrate anisotropic etching of Si. For 1.4 Hz operation, a room-temperature etch rate of 300 Å/min for Si~100! has been measured at a distance of 30 cm from the source. A 14% undercutting for room-temperature etching of Novolac-masked Si features was achieved under single-collision c...
متن کاملflexible beam robust loop shaping controller design using particle swarm optimization
in this paper a new strategy is proposed to design a fixed-structure robust controller for a flexible beam. robust controller designed by the conventional loop shaping method is not appropriate for a beam because of its high order and complicated form. fixed-structure loop shaping control in conjunction with particle swarm optimization (pso)algorithm is used to overcome this drawback. the ...
متن کاملBeam Intensity Profile Monitor
This paper describes an intercepting beam intenSity profile and position monitor which was developed at SLAC. It has excellent spatial resolution as well as signal efficiency. The instrument utilizes the electromagnetic cascade shower emission effect. Net charge leakage signals comparable in magnitude to the intercepted beam current are easily obtainable. The latest model of the instrument is d...
متن کاملAn alpha particle measurement system using an energetic neutral helium beam in ITER (invited).
An energetic helium neutral beam is involved in the beam neutralization measurement system of alpha particles confined in a DT fusion plasma. A full size strong-focusing He(+) ion source (2 A, the beam radius of 11.3 mm, the beam energy less than 20 keV). Present strong-focusing He(+) ion source shows an emittance diagram separated for each beamlet of multiple apertures without phase space mixi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
سال: 1989
ISSN: 0168-583X
DOI: 10.1016/0168-583x(89)90524-7