Neutral Point Overvoltages in Wye-Wye Connected Distribution Transformer Caused by Lightning Current in Low-Voltage Winding

نویسندگان

چکیده

Lightning strokes are a main source of transformer failures in distribution systems. The discharge lightning current through transformer's high-voltage (HV) side arresters leads to ground potential rise the tank. In case wye-wye connected with ungrounded HV neutral point, can drive low-voltage (LV) windings that an excessive voltage point by inductive transformation. Simulations measurement-based model demonstrate several times impulse test arise close strike overhead line. use LV surge combination proper grounding on HV-side effective ways reducing overvoltage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

More Forbidden Minors for Wye-Delta-Wye Reducibility

A graph is Y ∆Y reducible if it can be reduced to isolated vertices by a sequence of series-parallel reductions and Y ∆Y transformations. It is still an open problem to characterize Y ∆Y reducible graphs in terms of a finite set of forbidden minors. We obtain a characterization of such forbidden minors that can be written as clique k-sums for k = 1, 2, 3. As a result we show constructively that...

متن کامل

Phase Current Differential Protection for Transformers in Wye-delta Mode

For the current transformers (CTs) on the delta side measure the line current instead of the phase current, line current differential protection is adopted in transformers connected in wye-delta mode currently. However, the symmetry feature of inrush current in line current differential protection may invalidate the inrush current restrained criterion. A calculating method of current through de...

متن کامل

Transient Voltage Distribution in Transformer Winding (experimental Investigation)

Abstract In this work, the non-liner voltage distribution in transformer winding is investigated that occurs due switching and lightning. Transformer winding is modeled in the alternative transients program (ATP) version of Electromagnetic transients program (EMTPRV). EMTP software is used to simulate the very fast transient overvoltage. An experimental setup that consist of , Recurrent surge g...

متن کامل

Four-terminal reducibility and projective-planar wye-delta-wye-reducible graphs

A graph is Y Y-reducible if it can be reduced to a vertex by a sequence of series-parallel reductions and Y Y-transformations. Terminals are distinguished vertices which cannot be deleted by reductions and transformations. In this paper we show that four-terminal planar graphs are Y Y-reducible when at least three of the vertices lie on the same face. Using this result we characterize Y Y-reduc...

متن کامل

an investigation of over-voltages caused by lightning in transformer winding based on the monte carlo method

the paper presents simulation results for the propagation of lightning surges along a transmission line and the overvoltages generated in a transformer at the end of the line. it is shown that the monte carlo simulation method provides more realistic assessments than the deterministic methods. it has also been shown that increasing capacitance in transformers results in reduced levels of overvo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Delivery

سال: 2021

ISSN: ['1937-4208', '0885-8977']

DOI: https://doi.org/10.1109/tpwrd.2020.3027960