New Cf-252 neutron source shielding design based Monte Carlo simulation using material combination
نویسندگان
چکیده
منابع مشابه
Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملThe study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF
The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...
متن کاملMonte Carlo Calculations Using MCNP4B for an Optimal Shielding Design of a 14-MeV Neutron Source
The shielding for 14-MeV neutrons from a D-T generator at SLAC needs to be optimized in terms of shield thickness and cost. Shielding calculations were made using the MCNP4B Monte Carlo code and the ENDF/B-VI cross section set. A few materials were studied: iron, borated polyethylene, three types of normal and heavy concrete, and mixtures of iron and borated polyethylene. The effects of shieldi...
متن کاملdesign and simulation of photoneutron source by mcnpx monte carlo code for boron neutron capture therapy
introduction electron linear accelerator (linac) can be used for neutron production in boron neutron capture therapy (bnct). bnct is an external radiotherapeutic method for the treatment of some cancers. in this study, varian 2300 c/d linac was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for bnct. materials and methods photoneutron sources w...
متن کاملDesign and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: AIP Advances
سال: 2020
ISSN: 2158-3226
DOI: 10.1063/1.5144923