New method for evaluation of dissolved oxygen probe response forKLa determination
نویسندگان
چکیده
منابع مشابه
Urate oxidase electrode based on dissolved oxygen probe for urine uric acid determination.
A biosensor for the specific determination of uric acid in urine was developed using urate oxidase (EC 1.7.3.3) in combination with a dissolved oxygen probe. Urate oxidase was immobilized with gelatin by means of glutaraldehyde and fixed on a pretreated teflon membrane to serve as enzyme electrode. The electrode response was maximum when 50 mM glycine buffer was used at pH 9.2 and 35 degrees C....
متن کاملpolarographic method versus analytical method in determination of dissolved oxygen and n-no3
polarographic method is considered as an alternative laboratory technique for analytical method in determination of dissolved oxygen and n-n03. analytical method is a time consuming technique and is subject to several interferences due to some of constituents in sewage. in this laboratory research, the polar graphic technique with, mercury drop electrodes and titrometric method were applied in ...
متن کاملA new method for the continuous monitoring of blood glucose by measurement of dissolved oxygen.
Glucose concentration may be determined enzymatically by a glucose-oxidase procedure in which the amount of oxygen depletion from a solution saturated with oxygen is observed. The difference between the initial and final oxygen levels as detected by a polarographic oxygen analyzer is a measure of glucose concentration. Blood is sampled continuously by means of a double-lumen catheter inserted i...
متن کاملA Method for the Determination of Dissolved Carbon Dioxide
The determination of carbon dioxide, liberated in respiration experiments by aquatic animals, is especially difficult and uncertain. This is due partly to the fact that the quantity liberated is only a small fraction of the total quantity dissolved in the water in the form of carbonates, bicarbonates, and free carbon dioxide, and partly because the animals experimented on are often likely to gi...
متن کاملOptical Analyzer for Continuous Monitoring of Dissolved Oxygen in Aviation Fuel and Other Non-aqueous Media
A special sensitive element based on the novel composite material was created. The sensor has a linear calibration and is resistant to aliphatic hydrocarbons, in particular aviation fuel. A low cost and easy-to-implement method for calibrating the sensor was proposed. Temperature dependence of the oxygen mass transfer coefficient kL was measured for aviation fuel TS-1 (Russi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biotechnology and Bioengineering
سال: 1973
ISSN: 0006-3592,1097-0290
DOI: 10.1002/bit.260150519