منابع مشابه

Characteristics of Phase Current and its Application in Fault Section Location in Noneffectively Grounded Distribution Systems

Medium voltage distribution systems of some countries are mostly noneffectively grounded systems, and most of the distribution automation systems do not have the function of locating the fault section for single phase-to-ground fault. This paper presents a method of fault section location based on the characteristic of the phase current difference. It makes a deep analysis based on instantaneou...

متن کامل

A New Pulsating Power Elimination Method for Single-Phase PWM AC/DC Converters with Minimum Voltage and Current Stress

An inherent problem of single-phase rectifiers is the existence of a pulsating portion in the input power, which pulsates at twice the grid frequency. If this pulsating power is transferred to the DC-link, it causes a significant amount of second-order harmonic at the output voltage. Since in many applications, such a high level of DC oscillation is not acceptable, so the pulsating power must b...

متن کامل

fault location in power distribution networks using matching algorithm

چکیده رساله/پایان نامه : تاکنون روش‏های متعددی در ارتباط با مکان یابی خطا در شبکه انتقال ارائه شده است. استفاده مستقیم از این روش‏ها در شبکه توزیع به دلایلی همچون وجود انشعاب‏های متعدد، غیر یکنواختی فیدرها (خطوط کابلی، خطوط هوایی، سطح مقطع متفاوت انشعاب ها و تنه اصلی فیدر)، نامتعادلی (عدم جابجا شدگی خطوط، بارهای تک‏فاز و سه فاز)، ثابت نبودن بار و اندازه گیری مقادیر ولتاژ و جریان فقط در ابتدای...

A New Method Presentation for Fault Location in Power Transformers

Power transformers are among the most important and expensive equipments in the electric power systems. Consequently the transformer protection is an essential part of the system protection. This paper presents a new method for locating transformer winding faults such as turn-to-turn, turn-to-core, turn-totransformer body, turn-to-earth, and high voltage winding to low voltage winding. In this ...

متن کامل

Predictive Current Method for Single Open-phase Fault Detection in Permanent Magnet Synchronous Machine

Fault detection and post-fault operation are two functionalities of modern fault-tolerant system. In this paper, a new current predictive method for single open-phase fault (SOPF) detection in permanent magnet synchronous machine (PMSM) is presented. Major advantage of the proposed method is the capability of detecting open-phase fault in a few sampling intervals (few hundreds of μs). Also, an ...