New Sub-Module with Reverse Blocking IGBT for DC Fault Ride-Through in MMC-HVDC System

نویسندگان

چکیده

When integrating multi-grid renewable energy systems, modular multi-level converters (MMCs) are promising for high-voltage DC (HVDC) transmission. Because of the characteristics system, however, it is more difficult to prevent a fault at terminal than AC MMC. Accordingly, ride-through (FRT) strategy operation MMC in required stable system operation. In this paper, solution closed-circuit overcurrent caused by permanent line-to-line proposed. This method able reduce current through adjustment slope total voltage operating sub-module having lower switching losses and fewer passive devices compared with existing topologies. Additionally, equivalent circuit proposed scheme case fault, FRT mechanism explained. The feasibility technique was verified time-domain simulations implemented Powersim, Inc.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DC Fault Ride-through Capability and STATCOM Operation of a HVDC Hybrid Voltage Source Converter

HVDC transmission systems are becoming increasingly popular when compared to conventional AC transmission methods. HVDC voltage source converters (VSC) can offer advantages over traditional HVDC current source converter topologies; as such, it is expected that HVDC-VSCs will be further exploited with the growth of HVDC transmission. This paper presents the DC fault ride through capability and n...

متن کامل

Intelligent Controller Based Improved Fault Ride-through Capability of Hvdc System Connected to Weak Ac Grid

In the paper, a novel HVDC transmission system operating with weak ac system has been modeled with speed and precision & analyses the control strategy & performance of system, which is controlled using fuzzy. The system can feed a weak or even dead network under fluctuations and big variations of the input power. The fuzzy logic-based control of the system helps to optimize the efficiency of th...

متن کامل

Investigation on Fault-ride Through Methods for VSC-HVDC Connected Offshore Wind Farms

Recently, there has been a fast development and deployment of wind energy to meet the increasing electrical power demand and to limit the use of fossil fuels. More and more wind farms are planned far from shore because of good wind condition and less visual impact. This is so called offshore wind farm (OWF). In such a situation, high voltage direct current (HVDC) transmission is a favorable opt...

متن کامل

Control System Design and Fault-Ride-through Performance Analysis of Grid-Connected Microturbine Generation System

In recent years, microturbines as one the distributed generation sources have widly used. This paper investigates the control structure of the microturbine and analyzes its performance in grid-connected mode. In this way, first, the mechanical model of the microturbine is presented. Then, the electrical structure of the microturbine, consisting  of permanent magnet synchronous generator (PMSG) ...

متن کامل

Explosion proof housings for IGBT module based high power inverters in HVDC transmission application

Worldwide many attempts are taken to improve lifetime and power cycling capability of wire bonded IGBT modules. But even in very conservative inverter designs overload conditions may occur and cause damage to the inverter. In addition it is a fact that even the best design will reach its "end of life"

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2021

ISSN: ['1996-1073']

DOI: https://doi.org/10.3390/en14061551