New synchrotron powder diffraction facility for long-duration experiments

A new synchrotron X-ray powder diffraction instrument has been built and commissioned for long-duration experiments on beamline I11 at Diamond Light Source. The concept is unique, with design features to house multiple experiments running in parallel, in particular with specific stages for sample environments to study slow kinetic systems or processes. The instrument benefits from a high-bright...

متن کامل

Methyl­ergometrine maleate from synchrotron powder diffraction data

The title compound {systematic name: 9,10-didehydro-N-[1-(hydroxy-meth-yl)prop-yl]-d-lysergamide maleate}, C(20)H(26)N(3)O(2) (+)·C(4)H(3)O(4) (-), contains a large rigid ergolene group. This group consists of an indole plane connected to a six-membered carbon ring adopting an envelope conformation and N-methyl-tetra-hydro-pyridine where the methyl group is in an equatorial position. In the cry...

متن کامل

Alaptide from synchrotron powder diffraction data

THE TITLE COMPOUND [SYSTEMATIC NAME: (8S)-8-methyl-6,9-diaza-spiro-[4.5]decane-7,10-dione], C(9)H(14)N(2)O(2), consists of two connected rings, viz. a piperazine-2,5-dione (DKP) ring and a five-membered ring. The DKP ring adopts a slight boat conformation and the bonded methyl group is in an equatorial position. The five-membered ring is in an envelope conformation. In the crystal structure, in...

متن کامل

Multiple-detector System for Powder Diffraction Using Synchrotron Radiation

A multiple-detector system for powder diffraction using synchrotron radiation was built and has been operated at the Photon Factory in Tsukuba since May, 1995. The optics design is based on a flat-specimen-reflection geometry using parallel-beam, and the intensity data are collected by using asymmetric 2@stepscanning at a fixed incident angle. The multiple-detector system makes it possible to c...

متن کامل

10-Methyl­isoalloxazine 5-oxide from synchrotron powder diffraction data

THE TITLE COMPOUND [SYSTEMATIC NAME: 10-methyl-benzo[g]pteridine-2,4(3H,10H)-dione 5-oxide], C(11)H(8)N(4)O(3), consists of a large rigid isoalloxazine group which is approximately planar (r.m.s. deviation = 0.037 Å). In the crystal, inter-molecular N-H⋯O hydrogen bonds link the mol-ecules into centrosymmetric dimers. Dimers related by translation along the c axis form stacks through π-π inter-...