Noise-weighted Angular Differential Imaging
نویسندگان
چکیده
منابع مشابه
Angular Differential Imaging : a Powerful High - Contrast Imaging Technique
Angular differential imaging is a high-contrast imaging technique that reduces quasi-static speckle noise and facilitates the detection of nearby companions. A sequence of images is acquired with an altitude/azimuth telescope while the instrument field derotator is switched off. This keeps the instrument and telescope optics aligned and allows the field of view to rotate with respect to the ins...
متن کاملOptimal Acquisition Schemes in High Angular Resolution Diffusion Weighted Imaging
The recent challenge in diffusion imaging is to find acquisition schemes and analysis approaches that can represent non-gaussian diffusion profiles in a clinically feasible measurement time. In this work we investigate the effect of b-value and the number of gradient vector directions on Q-ball imaging and the Diffusion Orientation Transform (DOT) in a structured way using computational simulat...
متن کاملImpact of angular differential imaging on circumstellar disk images⋆
Context. Direct imaging of circumstellar disks requires high-contrast and high-resolution techniques. The angular differential imaging (ADI) technique is one of them, initially developed for point-like sources but now increasingly applied to extended objects such as disks. This new field of application raises many questions because the disk images reduced with ADI depend strongly on the amplitu...
متن کاملCardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging
Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magne...
متن کاملOptimal Short-Time Acquisition Schemes in High Angular Resolution Diffusion-Weighted Imaging
This work investigates the possibilities of applying high-angular-resolution-diffusion-imaging- (HARDI-) based methods in a clinical setting by investigating the performance of non-Gaussian diffusion probability density function (PDF) estimation for a range of b-values and diffusion gradient direction tables. It does so at realistic SNR levels achievable in limited time on a high-performance 3T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Research Notes of the AAS
سال: 2017
ISSN: 2515-5172
DOI: 10.3847/2515-5172/aa9d18