Non-separation assay for glycohemoglobin
نویسندگان
چکیده
منابع مشابه
Non-separation assay for glycohemoglobin.
The determination of glycohemoglobin [HbA1c, HbA1, or total glycohemoglobin (GHb)] has become an established procedure in the management of diabetes mellitus. Here, we describe the development of a simple, fluorescence, non-separation assay for the percentage of GHb (%GHb). The fluorescence of an eosin-boronic acid derivative when it was mixed with hemolysates of unwashed erythrocytes was quenc...
متن کاملNew enzymatic assay for glycohemoglobin.
BACKGROUND Previous methods to measure glycohemoglobin (GHb) have been time-consuming or imprecise; we therefore developed a new enzymatic assay for GHb. METHODS Blood cells were first hemolyzed, and hemoglobin was digested with protease to yield fructosyl amino acid. Fructosyl amino acid oxidase acts on the fructosyl amino acid and generates hydrogen peroxide, which reacts with chromogens in...
متن کاملFully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.
We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuring the quenching by heme of the static fluorescence from an added fluorophore....
متن کاملPotential Use of DNA Aptamer-Magnetic Bead Separation-PCR Assay for Salmonella Detection in Food
Background: Salmonella is one of the most common food-borne pathogens that can cause illness. In this study, the sensitivity and the specificity of Aptamer-Magnetic bead Separation-Polymerase Chain Reaction (AMS-PCR) method were determined for Salmonella spp. detection. Methods: Different concentrations of Salmonella enterica were mixed with streptavidin-magnetic beads coated with biotinylated...
متن کاملThree assays for glycohemoglobin compared.
Using 123 specimens, we compared the concordance of three different methods for determining glycohemoglobin (GHb): the Diamat (Bio-Rad Laboratories), an automated analyzer measuring HbA1c by cation-exchange chromatography; an assay with the IMx analyzer (Abbott Laboratories), based on boronate affinity binding; and an HPLC method measuring HbA1c by cation-exchange chromatography on a PolyCAT A ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 1998
ISSN: 0009-9147,1530-8561
DOI: 10.1093/clinchem/44.6.1302