Non Surgical Management of Mini Guide Wire Embolism with Self Made Guide Wire Snare

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Lost guide wire - lessons learned].

Central venous catheter placement is a relatively common procedure in current practice, but it is not devoid of risks. Utmost care must be taken to follow a correct technique, and only appropriately trained and/or supervised medical professionals should perform this invasive act. One of the possible complications, completely avoidable by appropriate care, is the intravascular loss of the guide ...

متن کامل

A high transmission wave-guide wire network made by self-assembly.

Polymer self-assembly of a 3D continuous gyroid morphology was replicated into a network consisting of hollow gold struts. This was achieved by first replicating a gyroid structured film into nickel. The Ni network was employed as an electrode for electrochemical Au deposition, followed by the removal of Ni. The resulting hollow network of plasmonic gold exhibited a substantial optical transmis...

متن کامل

Management of Retained Intervention Guide-wire: A Literature Review

Percutaneous coronary angioplasty is increasingly employed in the treatment of patients with complex coronary artery disease. Different steerable guide wires used to open occluded vessel and facilitate balloon and stent deployment. However, the guide-wire itself is not without hazard: it may perforate or dissect the vessel, but fracture or entrapment is uncommon. Its management depends on the c...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Annals of King Edward Medical University

سال: 2016

ISSN: 2079-0694,2079-7192

DOI: 10.21649/akemu.v9i3.1354