Electronic Energy Meter Based on a Tunnel Magnetoresistive Effect (TMR) Current Sensor
In the present work, the design and microfabrication of a tunneling magnetoresistance (TMR) electrical current sensor is presented. After its physical and electrical characterization, a wattmeter is developed to determine the active power delivered to a load from the AC 50/60 Hz mains line. Experimental results are shown up to 1000 W of power load. A relative uncertainty of less than 1.5% with ...
متن کاملThe Impact of Layer Number on Stray Inductance of DC-link Busbar in Power Converters
In high power converter design, low-inductance busbar connecting DC capacitors and power devices is the main concern to improve the quality of the whole power electronics system. This paper analyzes the impact of layernumber on the stray inductance of busbar taking a subway traction converter as example. The method of partial element equivalent circuit and the Q3D software are used to extract t...
متن کاملCurrent-Sensing Techniques for DC-DC Converters
Current sensing is one of the most important functions on a smart power chip. Conventional current-sensing methods insert a resistor in the path of the current to be sensed. This method incurs significant power losses, especially when the current to be sensed is high. Lossless current-sensing methods address this issue by sensing the current without dissipating the power that passive resistors ...
متن کاملCurrent - Fed Multi - Resonant DC - DC Converter *
A novel topology, Current-Fed MultiResonant DC-DC Converter (CF-MRC) was studied theoretically and experimentally. The main features of the proposed converter are an inherent protection against a short circuit at the output, a high voltage gain and zero voltage switching over a iarge range of output voitage. These characteristics make it a viable choice for the implementation of a high voltage ...
متن کاملExperimental Investigation of Porosity, Installation Angle, Thickness and Second Layer of Permeable Obstacles on Density Current
This study explored the effect of porosity and installation angle, thickness (dimension) and second layer of permeable obstacles on density current control and trapping in the laboratory. For this purpose, an insoluble suspended polymer and two types of groove and cavity obstacles made from plexiglass sheets were selected. The experiments were conducted with two different concentrations, five d...