Noninvasive Imaging of Epicardial and Endocardial Potentials With Low Rank and Sparsity Constraints
نویسندگان
چکیده
منابع مشابه
Experimental Validation of Noninvasive Epicardial and Endocardial Activation Imaging.
BACKGROUND Noninvasive imaging of cardiac activation before ablation of the arrhythmogenic substrate can reduce electrophysiological procedure duration and help choosing between an endocardial or epicardial approach. A noninvasive imaging technique was evaluated that estimates both endocardial and epicardial activation from body surface potential maps. We performed a study in isolated and in si...
متن کاملAccelerated MR parameter mapping with low-rank and sparsity constraints.
PURPOSE To enable accurate magnetic resonance (MR) parameter mapping with accelerated data acquisition, utilizing recent advances in constrained imaging with sparse sampling. THEORY AND METHODS A new constrained reconstruction method based on low-rank and sparsity constraints is proposed to accelerate MR parameter mapping. More specifically, the proposed method simultaneously imposes low-rank...
متن کاملReal-Time Phase Contrast Cardiovascular Flow Imaging with Joint Low-Rank and Sparsity Constraints
Real-Time Phase Contrast Cardiovascular Flow Imaging with Joint Low-Rank and Sparsity Constraints Bo Zhao, Aiqi Sun, Ke Ma, Rui Li, Anthony Christodoulou, Chun Yuan, and Zhi-Pei Liang Department of Electrical and Computer Engineering and Beckman Institute, University of Illinois at Urbana-Champaign, Urbana, IL, United States, Department of Biomedical Engineering and Center for Biomedical Imagin...
متن کاملBackground Subtraction Using Low Rank and Group Sparsity Constraints
Background subtraction has been widely investigated in recent years. Most previous work has focused on stationary cameras. Recently, moving cameras have also been studied since videos from mobile devices have increased significantly. In this paper, we propose a unified and robust framework to effectively handle diverse types of videos, e.g., videos from stationary or moving cameras. Our model i...
متن کاملNoninvasive epicardial and endocardial mapping of premature ventricular contractions
Aims The aim of the present study was to estimate the accuracy of a novel non-invasive epicardial and endocardial electrophysiology system (NEEES) for mapping ectopic ventricular depolarizations. Methods and results The study enrolled 20 patients with monomorphic premature ventricular contractions (PVCs) or ventricular tachycardia (VT). All patients underwent pre-procedural computed tomograph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Biomedical Engineering
سال: 2019
ISSN: 0018-9294,1558-2531
DOI: 10.1109/tbme.2019.2894286