NONINVASIVE СONTINUOUS BLOOD PRESSURE MONITORING DEVICE

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive blood pressure monitoring.

For more 20 years, noninvasive blood pressure (NIBP) monitors have been widely used in operating rooms and critical care units to closely monitor blood pressure in patients of all ages. Despite the widespread use of automated blood pressure monitors, clinicians continue to deliberate over the accuracy and reliability of automated NIBP devices compared to other methods of blood pressure determin...

متن کامل

Monitoring 24-hour blood pressure in a drug trial. Evaluation of a noninvasive device.

To test the usefulness of noninvasive ambulatory 24-hour blood pressure recording, the Del Mar Avionics system was used in a double-blind clinical trial in which 31 hypertensive patients were randomly allocated to receive placebo or pafenolol (25 mg or 50 mg), a novel, long-acting, highly selective beta-blocker, once daily. The results of 24-hour blood pressure and heart rate recording after 4 ...

متن کامل

A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery.

Continuous recording of arterial blood pressure (ABP) has many applications in cardiovascular physiology, but existing alternatives rely on measurements performed in the fingers or radial artery. Peripheral recordings have significant differences from central ABP regarding the pattern of the waveform and corresponding systolic and diastolic values. To address the need for noninvasive measuremen...

متن کامل

Noninvasive 24 hour ambulatory blood pressure monitoring: current status.

Noninvasive intermittent blood pressure monitoring was first developed 30 years ago.' It is now evolving from its former role as a somewhat esoteric research tool to becoming a clinically useful procedure for the evaluation ofhypertensive patients. In this review we outline its historical development, compare noninvasive 24-hour ambulatory blood pressure monitoring with the other available meth...

متن کامل

Ambulatory blood pressure monitoring evaluation of a semi-automated device.

The accuracy of a semi-automated ambulatory blood pressure monitoring device (the Instrumedix 'Personal Blood Pressure Transmitter') was assessed in 36 patients undergoing diagnostic cardiac catheterisation. Blood pressure readings measured by the device and by a standard manual sphygmomanometer were compared with simultaneous intra-aortic pressure measured directly via the catheter. No measure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Herald of Dagestan State Technical University. Technical Sciences

سال: 2015

ISSN: 2073-6185

DOI: 10.21822/2073-6185-2015-37-2-59-65