Nonlinear Analysis of Transmission Towers

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Analysis of Transmission Line Towers

The transmission line towers are one of the important life line structures in the distribution of power from the source to the various places for several purposes. The predominant external loads which act on these towers are wind and earthquake loads. In this present study tower is analyzed using Indian Standards IS: 875:1987(Wind Load), IS: 802:1995(Structural steel), IS:1893:2002 (Earthquake)...

متن کامل

Upgrading of Transmission Towers using Diaphragm Bracings

Many older transmission towers are designed based on tension-only bracing systems with slender diagonal members. However, the increased demand in power supply and changing global weather patterns mean that these towers require upgrading to carry the resultant heavier loading. The failure of a single tower can rapidly propagate along the line and result in severe damage that costs many millions ...

متن کامل

The Analysis of Nonlinear Synaptic Transmission

From the Department of Neurosciences, University of California, San Diego, La Jolla, California 92093, and the Department of Physiology and Biophysics, University of Texas Medical Branch, Galveston, Texas 77550. Dr. Krausz's present address is the Department of Physiology and Biophysics, University of Texas Medical Branch, Galveston, Texas 77550, and Dr. Friesen's is the Department of Biology',...

متن کامل

The analysis of nonlinear synaptic transmission

In order to characterize synaptic transmission at a unitary facilitating synapse in the lobster cardiac ganglion, a new nonlinear systems analysis technique for discrete-input systems was developed and applied. From the output of the postsynaptic cell in response to randomly occurring presynaptic nerve impulses, a set of kernels, analogous to Wiener kernels, was computed. The kernels up to thir...

متن کامل

Evaluating the Transient Impedance of Transmission Line Towers

The low-frequency methods used by most utilities nowadays for measuring the resistance of transmission line ground electrodes are inaccurate or cannot be applied when overhead groundwires are connected to the towers. Moreover, many of them are costly and time consuming. This paper proposes and compares two new methods for evaluating the transient impedance of transmission line towers. Both meth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of King Saud University - Engineering Sciences

سال: 1999

ISSN: 1018-3639

DOI: 10.1016/s1018-3639(18)30988-7