Normative reference values for hand grip dynamometry in Spain. Association with lean mass.
نویسندگان
چکیده
منابع مشابه
Reference values of hand-grip dynamometry and the relationship between low strength and mortality in older Chileans
Aim This study was aimed to set reference values of hand-grip strength by age and sex and validate cut points for risk of functional limitation and mortality in older Chileans. Methods This was a pooled analysis of four studies including 6,426 people ≥60 years of nondependent community-dwelling Chileans. After exclusion criteria, the final sample included 5,250 subjects, from whom 2,193 were ...
متن کاملMuscle strength: clinical and prognostic value of hand-grip dynamometry.
PURPOSE OF REVIEW Grip strength measured by dynamometry is well established as an indicator of muscle status, particularly among older adults. This review was undertaken to provide a synopsis of recent literature addressing the clinical and prognostic value of hand-grip dynamometry. RECENT FINDINGS Numerous large-scale normative grip strength projects have been published lately. Other recent ...
متن کاملHand-Held Dynamometry Isometric Torque Reference Values for Children and Adolescents
PURPOSE To establish hand-held dynamometry (HHD) maximal isometric muscle torque (MIT) reference values for children and adolescents who are developing typically. METHODS The MIT of 10 upper and lower limb muscle groups was assessed in 351 Caucasian youth (4 years 2 months to 17 years) using a standardized HHD protocol, previously shown to be feasible, valid, and reliable. RESULTS The mean ...
متن کاملNormative Reference Values for Healthy Argentinian Children
A comprehensive assessment of central auditory processing disorders includes parent questionnaires. The Scale of Audi tory Behaviors (SAB) was developed to evaluate the limitations and difficulties perceived by guardians of children in everyday activities.The aim of the study was to provide normative data for the SAB for Argentinian healthy children. The parents and guardians of eighty-four chi...
متن کاملHand-held myometry: reference values.
In thirteen major muscle groups of 50 healthy females and 50 males, aged 20-60 years, maximum voluntary contraction was measured with a hand-held dynamometer. The intrasession variation, the left-right variation, and the fifth and fiftieth centile values were calculated. The ratio of two observations within one session ranged from 0.85 to 1.18 and the ratio of left to right ranged from 0.82 to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nutrición Hospitalaria
سال: 2018
ISSN: 1699-5198,0212-1611
DOI: 10.20960/nh.1052