Novacor left ventricular assist device inflow valve endocarditis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic left ventricular assist device inflow obstruction.

A 72-year-old man with a history of rheumatic heart disease , prior bioprosthetic mitral and aortic valve replacement , severe nonischemic dilated cardiomyopathy (left ventricular [LV] ejection fraction 5%), and a history of ven-tricular tachycardia (VT) underwent implantation of a continuous flow LV assist device (LVAD; HeartMate II; Thoratec Corporation) as destination therapy for severe hear...

متن کامل

Diagnosis and management of left ventricular assist device valve-endocarditis: LVAD valve replacement.

A 57-year-old man who has been wearing a Novacor N100 left ventricular assist device (LVAD) for more than 3 years suffered from LVAD endocarditis. Only by immunoscintigraphic methods was it possible to localize the septic focus. After successful exchange of in- and outflow tract valves, the infection was eradicated. Microscopic investigation confirmed the scintigraphic findings: Gram-positive b...

متن کامل

Transcatheter aortic valve replacement performed via left ventricular assist device inflow cannula.

A 62-year-old woman with a history of lung cancer, prior surgical aortic valve replacement with a 23-mm Hancock (Medtronic, Inc, Minneapolis, MN) porcine valve, and non-ischemic cardiomyopathy supported with a HeartMate II destination therapy left ventricular assist device (LVAD; Thoratec Corporation, Pleasanton, CA) presented with hemolytic anemia (hemoglobin, 6.8 g/dL; lactate dehydrogenase, ...

متن کامل

Right ventricular support after implantation of a Novacor Left Ventricular Assist Device.

The objective was to determine which factors might help to predict the need for mechanical right ventricular support following insertion of a left ventricular assist device (LVAD). A retrospective analysis was performed on 24 patients with cardiomyopathies who had insertion of a LVAD as a bridge to heart transplantation at Presbyterian University Hospital during the period 1987 to 1991. Group...

متن کامل

[Prosthetic aortic valve thrombosis after left ventricular assist device implantation].

Rev Esp Cardiol. 2005;58(7):863 863 A 54-year-old man had undergone aortic valve replacement with a valve graft according to the Bentall-Bono technique because of severe stenosis and aneurysm of the ascending aorta 14 years ago. He had been hospitalized several times over the past 2 years for congestive heart failure and progressive worsening of left ventricular (LV) ejection fraction, clinical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: European Journal of Cardio-Thoracic Surgery

سال: 2009

ISSN: 1010-7940

DOI: 10.1016/j.ejcts.2009.01.028