Novel Approach for Anterior Chamber Angle Analysis
نویسندگان
چکیده
منابع مشابه
Novel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA).
OBJECTIVE To describe a novel approach to measuring anterior chamber angle dimensions and configurations. METHODS Sixty-nine images were selected randomly from the ultrasound biomicroscopic image database to develop the algorithm. Thirty images were selected for further analyses. The value of each pixel of the 8-bit grayscale ultrasound biomicroscopic images was quantized into 0 (black) or 1 ...
متن کاملAutomated analysis of angle closure from anterior chamber angle images.
PURPOSE To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. METHODS In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classifi...
متن کاملAnterior Chamber Angle Assessment Techniques
The anterior chamber angle is the actual anatomical angle created by the root of the iris and the peripheral corneal vault. Within it lie the structures involved in the outflow passage of the aqueous, namely the trabecular meshwork and the Schlemm’s canal (figure 1). The depth of the angle in a healthy eye is approximately 30°, with the superior part usually less deep than the inferior half. Ho...
متن کاملP 311 The anterior chamber angle analysis in myopia
~UklQSE : I~ka Ocular Ptesstire (KM’) veries through out the nycthemeral. Noclutnal sludtes desctibed recehtty an elevation of ltlP dutlttg sleep. Howevet, no lepokt on sleep pstlerns associated nlth Ihe measurement of IOP kds made. WC report hcte, 2 studies ntt haurly measukmenl al IOP over a pertnd ol24 hours. WHODS : Twelve young tdltsnsians subjects (dged 20,6f 0,3 Yeats), lwelvk uldet tdut...
متن کاملForeign Body Embedded in Anterior Chamber Angle
Introduction. We present a case of a metallic foreign body embedded in the anterior chamber angle. After standing in close proximity to a construction worker breaking a tile, a 26-year-old woman using soft contact lens for the correction of mild myopia presented to emergency department for evaluation of a foreign body sensation of her right eye. Methods and Results. Diagnosis was confirmed by g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Archives of Ophthalmology
سال: 2006
ISSN: 0003-9950
DOI: 10.1001/archopht.124.10.1395