Novel device, a temporary guidewire fixator

A novel device for distal fixation of a guidewire was tested in regards to deployment and retrieval, deposition in the blood stream and force of fixation in a pig model. Eleven pigs were subjected to full anaesthesia and heparinized to active clotting time 250-350 s. Uninterrupted blood flow during 4 h deposition was assessed by angiography and inspected for thrombus deposition upon retrieval. ...

متن کامل

Safety and Functionality of a Guidewire Fixator

OBJECTIVE A new endovascular tool, the Liungman Guidewire Fixator, has been developed to simplify endovascular treatment in complex aortic aneurysms. The device has been extensively tested in bench models and animal trials. To verify the safety and functionality demonstrated in the porcine model, the device was tested in ten patients undergoing endovascular aortic repair (EVAR) or fenestrated e...

متن کامل

Precannulated Fenestrated Endovascular Aneurysm Repair Using Guidewire Fixator

OBJECTIVE By using a guidewire fixator, the distal guidewire position can be secured in an artery. This new principle enables a method for fenestrated endovascular aortic repair where the connection between the aortic branches and the stent graft fenestrations is made before inserting and deploying the stent graft. METHODS This is conducted using a fenestrated stent graft with preloaded cathe...

متن کامل

A Novel Portable Scissors-Type Fruit Picking Device

At present, the fruit picking in most countries still largely relies on manual operation. Manual fruit picking can protect the fruits from damage during the operation process. However, it is time-consuming and labor-intensive, and poses a potential safety risk to the workers while working at heights not reachable. Therefore, a variety of fruit picking machines and platforms have been developed ...

متن کامل

A Novel Guidewire Aiming Device to Improve the Accuracy of Guidewire Insertion in Femoral Neck Fracture Surgery Using Cannulated Screw Fixation

BACKGROUND The aim of this study was to improve the accuracy of guidewire insertion in the femoral neck fracture surgery using cannulated screw fixation. MATERIAL AND METHODS A novel aiming device was designed and manufactured. Between January 2010 and June 2012, 64 femoral neck fracture patients were included into the study. All 64 patients were divided into 2 groups randomly. The aiming devic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Vascular

سال: 2016

ISSN: 1708-5381,1708-539X

DOI: 10.1177/1708538116629265