Novel method for restraining 35 kV shunt reactor switching overvoltage – phase controlled breaker
نویسندگان
چکیده
منابع مشابه
Estimation of New Weighted Controlled Switching Overvoltage by RBFN Model
Mitigating switching overvoltages (SOVs) and conducting well-suited insulation coordination for handling stresses are very important in UHV transmission Lines. The best strategy in the absence of arresters is controlled switching (CS). Although elaborate works on electromagnetic transients are considered in the process of designing transmission systems, such works are not prevalent in day-to-da...
متن کاملField Experiments on 10 kV Switching Shunt Capacitor Banks Using Ordinary and Phase-Controlled Vacuum Circuit Breakers
During the switching on/off of shunt capacitor banks in substations, vacuum circuit breakers (VCBs) are required to switch off or to switch on the capacitive current. Therefore, the VCBs have to be operated under a harsh condition to ensure the reliability of the equipment. This study presents a complete comparison study of ordinary and phase-controlled VCBs on switching 10 kV shunt capacitor b...
متن کاملMultiprocessor Based Architecture for Controlled Switching of Circuit Breaker
Circuit Breaker is one of the most critical elements of power industry. Controlled Switching of grid voltage and grid current is the best solution to prevent the high inrush current and over voltages. This paper describes the Controlled Switching of Circuit Breaker by using multiprocessor based architecture. With this architecture early detection of most of major fault is feasible; it is also p...
متن کاملA Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کاملShunt Capacitance for a Practical 380 kV System
It is well known that shunt capacitance is both socially and economically beneficial to power system network. These devices reduce the apparent power (S) which is produced by generators allowing more customers to be served and increasing the income of electrical companies. Shunt compensation units have to be connected to carefully selected substations to result in a high degree of reactive powe...