Novel Robust Internal Calibration Procedure for Precise FT-IR Measurements of Nitrogen Impurities in Diamonds
نویسندگان
چکیده
FT-IR spectroscopy is the basic finger-print method for qualitative and quantitative analysis of nitrogen, boron, hydrogen impurities in natural synthetic diamonds. In measurements impurity concentrations, external standard samples are required calibration procedure during analysis. this study, double-phonon mid-IR absorption coefficient optical phonons diamond host matrix, robust internal standard, was accurately measured tens diverse samples, thus enabling precise calibrated ultra-low detectable concentrations.
منابع مشابه
Calibration for IR measurements of OH in apatite
In this work, we have calibrated the infrared (IR) method for determining OH concentrations in apatite with absolute concentrations obtained through elastic recoil detection (ERD) analysis. IR spectra were collected on oriented, single-crystal apatite samples using polarized transmission infrared spectroscopy. The weight percent H2O is 0.001199 ± 0.000029 (the error is given at 1σ level hereaft...
متن کاملSignal - to - noise ratio in FT - IR measurements
[6]. ABSTRACT: The influence of different useful recording parameters in Fourier transform infrared spectra, on the signal-to-noise ratio is considered. We particularly studied the evolution of the signal to noise ratio with the spectral resolution, the transmission of different samples, the intensity of the background and the number of scans. This will allow an optimal extraction of spectral i...
متن کاملTranspulmonary thermodilution assessments: precise measurements require a precise procedure
When incorporating the values of a hemodynamic parameter into the care of patients, the precision of the measurement method should always be considered. A prospective analysis in the previous issue of Critical Care showed that the precision of transpulmonary thermodilution (TPTD) allows for reliable mean values if a standardised procedure is used. The present finding has a physiological basis, ...
متن کاملWhat Is an Ft-ir and an Ft-ir Spectrometer?
An FT-IR Spectrometer is an instrument which acquires broadband NIR to FIR spectra. Unlike a dispersive instrument, i.e. grating monochromator or spectrograph, an FT-IR Spectrometer collects all wavelengths simultaneously. This feature, called the Multiplex or Felgett Advantage, is discussed in detail on page 3. FT-IR Spectrometers are often simply called FT-IRs. But for the purists, an FT-IR (...
متن کاملEffect of interstitial impurities on internal friction measurements in niobium
Measurements of internal friction as a function of temperature were carried out in samples of niobium containing different amounts of interstitial solutes (oxygen and nitrogen) and one sample of niobium containing initially only nitrogen as interstitial solute. The experimental spectra of internal friction as a function of temperature were obtained with a torsion pendulum of the inverted Kê-typ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemosensors
سال: 2023
ISSN: ['2227-9040']
DOI: https://doi.org/10.3390/chemosensors11060313