Numerical Analysis and Design of Moving Contactless High Power Transformer
نویسندگان
چکیده
منابع مشابه
Design and analysis of contactless transformer using series resonant converter
A loosely contactless transformer with a large air gap has small magnetizing inductance and large leakage inductance comparing with a closely conventional transformer. This paper focus on analysis, design and measurement results of the loosely winding contactless transformer using resonant converter. Finally, the experimental set up is built to transfer power of 300 W over the different gap var...
متن کاملFinite Element Analysis of a Contactless Transformer
Inductively coupling power transfer is an emerging technique, which enables power transfer to loads through air. The contactless transformer is the key component of it, and the design of a transformer is a timeconsuming work with a large number of tests. In this paper, a design method of contactless transformer with finite element analysis is presented. First the contactless transformer model i...
متن کاملanalysis of power in the network society
اندیشمندان و صاحب نظران علوم اجتماعی بر این باورند که مرحله تازه ای در تاریخ جوامع بشری اغاز شده است. ویژگیهای این جامعه نو را می توان پدیده هایی از جمله اقتصاد اطلاعاتی جهانی ، هندسه متغیر شبکه ای، فرهنگ مجاز واقعی ، توسعه حیرت انگیز فناوری های دیجیتال، خدمات پیوسته و نیز فشردگی زمان و مکان برشمرد. از سوی دیگر قدرت به عنوان موضوع اصلی علم سیاست جایگاه مهمی در روابط انسانی دارد، قدرت و بازتولید...
15 صفحه اولDesign of New Contactless Power Supply System
A design method for new contactless power supply systems is proposed. Such systems realize contactless power supply to electrical apparatus, which may keep still or moving relative to the power source. Optimized electric parameters are determined to maximize the power transfer capability. Secondary compensation may be taken to further improve the power transfer characteristics. The applicabilit...
متن کاملOptimum Design of a High-Power, High-Frequency Transformer - Power Electronics, IEEE Transactions on
A procedure for optimum design of a high-power, high-frequency transformer is PresentedThe Procedure is based on both electrical and thermal processes in the transformer and identifies a) the VA-rating of ferrite cores in relation to the operating frequency, , , ) the optimum flux density in the core, and c) the optimum current densities of the windings providing maximum transformer efficiency....