Numerical optimization of a transcritical CO 2 /propylene cascaded refrigeration-heat pump system with economizer in HT cycle
نویسندگان
چکیده
منابع مشابه
Thermoeconomic optimization and exergy analysis of transcritical CO2 refrigeration cycle with an ejector
The purpose of this research is to investigate thermoeconomic optimization and exergy analysis of transcritical CO2 refrigeration cycle with an ejector. After modeling thermodynamic equations of elements and considering optimization parameters of emerging temperature of gas of cooler (Tgc) , emerging pressure of cooler's gas (Pgc) , and eva...
متن کاملThermoeconomic optimization and exergy analysis of transcritical CO2 refrigeration cycle with an ejector
The purpose of this research is to investigate thermoeconomic optimization and exergy analysis of transcritical CO2 refrigeration cycle with an ejector. After modeling thermodynamic equations of elements and considering optimization parameters of emerging temperature of gas of cooler (Tgc) , emerging pressure of cooler's gas (Pgc) , and eva...
متن کاملPerformance evaluation of irreversible cascaded refrigeration and heat pump cycles
This communication presents finite time thermodynamic optimization of irreversible cascaded refrigeration and heat pump cycles having source/sink thermal reservoirs of finite heat capacitance. A general expression for the optimum coefficient of performance of the refrigerator/heat pump is derived at minimum power input and given cooling/heating load conditions, respectively. External irreversib...
متن کاملOptimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications
Energetic and exergetic analyses as well as optimization studies of a transcritical carbon dioxide heat pump system are presented in this article. A computer code has been developed to obtain sub-critical and super-critical thermodynamic and transport properties of carbon dioxide. Estimates for irreversibilities of individual components of the system lead to possible measures for performance im...
متن کاملUsing Carbon Dioxide in a Transcritical Vapor Compression Refrigeration Cycle
For most of the last fifty years, refrigeration and heat pump systems have been based on cycles using a fluorocarbon as the working fluid. Hovvever, with the discovery that fluorocarbons may have a profoundly detrimental effect on the earth ·s atmosphere. it has become necessary to find a suitable replacement for a fluorocarbon based refrigeration cycle. Such a replacement must perform comparab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sadhana
سال: 2015
ISSN: 0256-2499,0973-7677
DOI: 10.1007/s12046-014-0319-5