Observations upon the interface between bone and polymethylmethacrylate cement

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of polymethylmethacrylate bone cement in modern orthopaedic surgery.

Polymethylmethacrylate remains one of the most enduring materials in orthopaedic surgery. It has a central role in the success of total joint replacement and is also used in newer techniques such as percutaneous vertebroplasty and kyphoplasty. This article describes the current uses and limitations of polymethylmethacrylate in orthopaedic surgery. It focuses on its mechanical and chemical prope...

متن کامل

Regional variation in shear strength of the bone-polymethylmethacrylate interface.

Many investigators consider the polymethylmethacrylate-bone interface the weakest link in the bone-cement-implant system. Push-out tests, frequently used for in vitro evaluation of the bone-cement interface, produced inconsistent results of shear strength. Therefore, a more reliable model for testing the shear failure of the interface was developed. Better understanding of intrinsic variations ...

متن کامل

Porosity reduction in bone cement at the cement-stem interface.

The fatigue failure of bone cement, leading to loosening of the stem, is likely to be one mode of failure of cemented total hip replacements. There is strong evidence that cracks in the cement are initiated at voids which act as stress risers, particularly at the cement-stem interface. The preferential formation of voids at this site results from shrinkage during polymerisation and the initiati...

متن کامل

Experimental micromechanics of the cement-bone interface.

Despite the widespread use of cement as a means of fixation of implants to bone, surprisingly little is known about the micromechanical behavior in terms of the local interfacial motion. In this work, we utilized digital image correlation techniques to quantify the micromechanics of the cement-bone interface of laboratory-prepared cemented total hip replacements subjected to nondestructive, qua...

متن کامل

Failure of the cement-bone interface.

We report the early failure, at a mean of 37 months, of 17 femoral prostheses due to aseptic loosening at the cement-bone interface. In every case the prosthesis had been manufactured with a surface coating designed to enhance the strength of the cement-prosthesis interface. It is postulated that improving the bond at the cement-prosthesis interface may transfer increased stress to the cement-b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Bone and Joint Surgery. British volume

سال: 1982

ISSN: 0301-620X,2044-5377

DOI: 10.1302/0301-620x.64b4.7096429