OC-0359: Microdosimetric evaluation of intermediate-energy brachytherapy sources using Geant4-DNA
نویسندگان
چکیده
منابع مشابه
Preliminary Investigation of Microdosimetric Track Structure Physics Models in Geant4-DNA and RITRACKS
The major differences between the physics models in Geant4-DNA and RITRACKS Monte Carlo packages are investigated. Proton and electron ionisation interactions and electron excitation interactions in water are investigated in the current work. While these packages use similar semiempirical physics models for inelastic cross-sections, the implementation of these models is demonstrated to be signi...
متن کاملCalculation and evaluation of energy deposition and S-value caused by low-energy electrons in a multicellular model using Geant4-DNA
Today, targeted radiation therapy (TRT) methods for cancer treatment, besides the goal of completely destroying the target tumor, attempts to prevent nearby healthy cells from exposure to ionizing radiation as far as possible. Hence, short-range charged particles, such as low-energy electrons that are suited to achieving these two goals together, play an important role in TRT and so, adoption o...
متن کاملEffectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code
Background and Objective: The most common intravascular brachytherapy sources include 32P, 188Re, 106Rh and 90Sr/90Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended.Method: Four materials including...
متن کاملInvestigation of the direct DNA damages irradiated by protons of different energies using geant4-DNA toolkit
Background: The total yields of direct Single-Strand Breaks (SSBs) and Double-Strand Breaks (DSBs) in proton energies varying from 0.1 to 40 MeV were calculated. While other studies in this field have not used protons with energy less than 0.5 MeV, our results show interesting and complicated behavior of these protons. Materials and Methods: The simulation has been done using the Geant4-DNA too...
متن کاملhazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2017
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(17)30801-0