OMEGA SiPM readout ASICs
نویسندگان
چکیده
Abstract The paper describes various multi-channel ASICs designed by OMEGA laboratory and WEEROC company to readout SiPM or MPPC-based detectors used in particle physics astrophysics experiments.
منابع مشابه
Advanced Readout ASICs for Multielement CZT Detectors
A generation of high performance front-end and read-out ASICs customized for highly segmented CdZnTe sensors is presented. The ASICs, developed in a multi-year effort at Brookhaven National Laboratory, are targeted to a wide range of applications including medical, safeguards/security, industrial, research, and spectroscopy. The front-end multichannel ASICs provide high accuracy low noise pream...
متن کاملScintillator Tile Hadron Calorimeter with Novel SiPM Readout
The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a large scale. We present the design of the HCAL and report on measured properties of more than 10 thousand SiPMs. We discuss the SiPM efficiency, gain, cross-ta...
متن کاملA CMOS Baseline Holder (BLH) for Readout ASICs
As a result of a cooperation between Brookhaven National Laboratory and eV Products a generation of high performance readout ASICs was developed. One of the novel circuit solutions implemented in the ASICs is the baseline holder (BLH), a system which provides setting and stabilization of the output baseline both at low frequency and at high rate operation. The BLH is conceptually different from...
متن کاملDepth of interaction determination in monolithic scintillator with double side SiPM readout
BACKGROUND Monolithic scintillators read out by arrays of photodetectors represent a promising solution to obtain high spatial resolution and the depth of interaction (DOI) of the annihilation photon. We have recently investigated a detector geometry composed of a monolithic scintillator readout on two sides by silicon photomultiplier (SiPM) arrays, and we have proposed two parameters for the D...
متن کاملSiPM technology applied to radiation sensor development
The Silicon Photo-Multiplier (SiPM) being yet in its infancy, a full protocol for the sensor characterization has been developed and implemented at the Physics Department of Universita’ dell’Insubria. Sensors from different producers have been analyzed and compared, in view of the integration in the instruments for radiation detection. Exemplary illustrations are reported here, together with th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research
سال: 2021
ISSN: ['1872-9576', '0168-9002']
DOI: https://doi.org/10.1016/j.nima.2020.164628