ON MECHANISM OF X-BRACED FRAME WITH HYSTERETIC DAMPER AND ITS ELASTO-PLASTIC BEHAVIOR : Part 2 Shear connected braced frame
نویسندگان
چکیده
منابع مشابه
Response Modification Factor of Chevron Braced Frame With Pall Friction Damper
Response modification factors (R-factor) are used in current seismic building codes to reduce earthquake forces associated with seismic design level to determine force levels. In recent years, many authors have shown great interest in the development of seismic structural systems and several theoretical and experimental studies have been conducted to investigate performance of dampers but littl...
متن کاملAssessment of Seismic Behavior of Eccentrically Braced Frame with Double Vertical Link (dv-ebf)
This paper is an experimental study on the behavior of vertical shear link in the single and double configurations. There have been three specimens selected for examining the effects of different details .The first specimen was an I section with no stiffener, while the second specimen composed of I section with stiffeners designed according to AISC 2005. Third specimens were composed of two I s...
متن کاملOptimal placement of post-tensioned self-centering yielding braced systems for braced frame structures
The experience of past prominent earthquakes establishes the fact that the structure’s catastrophes and casualties can be dramatically decreased through the use of self-centering systems. A promising post-tensioned self-centering yielding braced system (PT-SCYBS) has been developed, comprising of two main components, including the post-tensioned wires, exhibiting the desirable self-centering pr...
متن کاملNumerical Modelling of Timber Braced Frame Masonry Structures (Dhajji Dewari)
This paper presents numerical modeling technique for Dhajji-Dewari structures (timber-braced rubble stone masonry), and its application for the evaluation of in-plane force-deformation capacity of Dhajji wall panels of different configuration of bracings. Dhajji structures are mainly composed of vertical and horizontal timber posts and braced using diagonal bracings and horizontal studs. Wall o...
متن کاملEffect of column-foundation connection stiffness on seismic performance of rocking steel braced frame
Residual drifts after severe earthquakes interrupt serviceability of buildings. Retrofitting of such buildings is in many cases very difficult and consumes lots of time and money. Recently, there are some attempts to develop the seismic design procedures to not only satisfy life safety criteria but also lead to more economical buildings. One of these modern methods of improving seismic performa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2001
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.66.153_1