On Ununited Fracture
نویسندگان
چکیده
منابع مشابه
On the Treatment of Ununited Fracture by Passive Congestion
When Bier of Kiel introduced his excellent method of treating tubercular joint affections by means of passive congestion, he indicated that the method he adopted had been formerly employed by others for the cure of ununited fracture. This mode of treatment, although apparently well known on the Continent, is somewhat novel here, and the two cases which follow may serve to illustrate the advanta...
متن کاملUnunited Anconeal Process, Ununited Medial Coronoid Process, Ununited Medial Epicondyle, Patella Cubiti, and Sesamoidal Fragments of the Elbow
Osteoarthritis of the elbow has been recognized byveterinarians for many years to be a developmental diseasesyndrome in young dogs. It was not until the middle 1950s,however, that progress was made toward defining specificpathologic etiologies, with the elucidation of the problem of"ununited anconeal process." Originally thought to beanalogous to patella cubiti in humans,(13)the true nature of ...
متن کاملVacuum phenomenon as a sign of an ununited, unstable dens fracture.
Gas within a degenerated intervertebral disk (vacuum phenomenon) or within a synovial joint subjected to traction is a common radiographic finding [1-6] . Gas produced by bacterial action has been described as a sign of osteomyelitis or soft-tissue infection [7] . Intraosseous gas as a physical phenomenon has also been identified in patients with ischemia or malignancy [8-10]. The purpose of th...
متن کاملThe Efficacy of Ununited Tibial Fracture Treatment Using Pulsing Electromagnetic Fields
Thirty ununited tibial fractures with a median time since injury of 18±9 months were treated by electrical stimulation using pulsing electromagnetic field therapy. Union was achieved in 25 cases(83.3%)in a median interval of 8.6±3.2 months. Patient age and gender, the presence of surgical hardware, length of disability, and the number of surgical procedures did not affect the outcome. Ununited ...
متن کاملExchange nailing of ununited fractures.
Exchange nailing is most appropriate for a nonunion without substantial bone loss. There is no clear consensus regarding the use of exchange nailing in the presence of active, purulent infection. The exchange nail should be at least 1 mm larger in diameter than the nail being removed, and it has been recommended that it be up to 4 mm larger when the nail being removed was greatly undersized. Ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BMJ
سال: 1859
ISSN: 0959-8138,1468-5833
DOI: 10.1136/bmj.s4-1.131.519