Online Estimation of Cable Harmonic Impedance in Low-Voltage Distribution Systems

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification and Evaluation of Human Errors in Low Voltage Distribution Systems using FUZZY-HEART Technique

Electricity-related occupational accidents are the fifth leading cause of occupational deaths. One of the major causes of occupational accidents is human error. That is why the human role as a cause of the accident is so important and must be considered during risk assessment. The purpose of this study is to present a Fuzzy-HERAT human error assessment method, which can be used to assess the pr...

متن کامل

coordination of protective schemes in distribution and subtransmission systems including distributed generation

نصب منابع پراکنده در سیستم های توزیع و فوق توزیع علاوه بر مزیت های فراوان، مشکلاتی را هم به همراه دارد. یکی از این مشکلات تأثیر این منابع روی اندازه جریان های اتصال کوتاه است. به طور معمول از حفاظت های مبتنی بر اصل جریان زیاد در سیستم های توزیع و فوق توزیع استفاده می شود. از مهمترین طرح های حفاظتی استفاده شده در فیدرهای توزیع، حفاظت فیوز- ریکلوزر است. همچنین از طرح های حفاظتی جریان زیاد جهتی در...

Methods for Estimation of Voltage Harmonic Components

The estimation of harmonic components of power voltage signals is one of the measurements prescribed by the power quality (PQ) standards (IEC 61000-4-30, 2008). In general, the harmonic components originate from non-linear elements connected to the power system such as non-linear loads (e.g., switched-mode power supplies) or transformers. An example of a distorted voltage measured in an office ...

متن کامل

Maximum PV-penetration in low-voltage cable networks

As a consequence of the increasing amount of PV-systems connected to the LV-network the question arises whether these networks are able to cope with large amounts of PV. In this paper it is investigated whether problems have to be expected in typical LV networks in the Netherlands. It is shown that exceeding of the regulatory voltage levels is the first limiting factor for integration of PV, fo...

متن کامل

Low-Swing Voltage-Mode Driver Impedance Control

Transmitters are used to pass data stream through transmission lines in either current or voltage mode. In high data rate applications, the output impedance of transmitters should match the transmission lines’ characteristic impedance and should be tunable in order to compensate the process, voltage, and temperature variations. The multiplexing technique can be used to extend transmitters signa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Instrumentation and Measurement

سال: 2020

ISSN: 0018-9456,1557-9662

DOI: 10.1109/tim.2019.2926690