Optimal application of fluid viscous dampers in tall buildings incorporating integrated damping systems
نویسندگان
چکیده
منابع مشابه
OPTIMUM LAYOUT OF NONLINEAR FLUID VISCOUS DAMPER FOR IMPROVEMENT THE RESPONSES OF TALL BUILDINGS
The utilization of passive energy dissipation systems has been created a revolution in the structural engineering industry due to their advantages. Fluid Viscous Damper (FVD) is one of these control systems. It has been used in many different industries, such as the army, aerospace, bridge, and building structures. One of the essential questions about this system is how it can combine with the ...
متن کاملEquivalent Damping Ratios of Structures with Supplemental Viscous Dampers
The current design formulas such as those provided by FEMA273/274 for building structures with supplemental viscous dampers were derived based on the shear building assumption. However, for medium-rise to high-rise buildings that deform in a combined form of shear and bending when subjected to seismic loading, the design using existing formulas may result into an actual damping ratio much lower...
متن کاملperformance evaluation of viscoelastic and friction passive damping systems in vibration control of tall buildings
this paper provides a comparison of the maximum inter-story drifts and tip acceleration of both a 16 and 30 stories building each with different structural systems; hybrid r.c moment frame with shear walls and hybrid steel frame with shear walls and x bracing which are equipped by passive dampers. each of the building models were analyzed as fully non-linear structures for variety of dampers pl...
متن کاملThe Effect of Viscous Dampers on Improvement of the Behavior of Tall Belt Truss Structures
Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure un...
متن کاملThe Effect of Viscous Dampers on Improvement of the Behavior of Tall Belt Truss Structures
Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure under e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Structural Design of Tall and Special Buildings
سال: 2021
ISSN: ['1541-7794', '1541-7808']