Optimal PMU Placement for Power System Dynamic State Estimation by Using Empirical Observability Gramian

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Multistage Scheduling of Pmu Placement for Power System Observability

The standards of power system monitoring, control and protection are elevated by Phasor Measurement Units (PMUs) as an auspicious tool. It is the purpose of this paper to determine the optimal number and locations of PMUs so as to make the system measurement model observable and also estimate the power system state. The proposed modelling approach which models PMU placement as an integer linear...

متن کامل

An optimal PMU placement technique for power system observability

0142-0615/$ see front matter 2012 Elsevier Ltd. A http://dx.doi.org/10.1016/j.ijepes.2012.03.011 ⇑ Corresponding author. E-mail address: [email protected] (B.K. Saha Roy Power system state estimation with exclusive utilization of synchronous phasor measurements demands that the system should be completely observable through PMUs only. To have minimum number of PMUs, the PMU placement issue in an...

متن کامل

Observability of power systems with optimal PMU placement

Phasor Measurement Units (PMUs) are measuring devices that, when placed in electrical networks, observe their state by providing information on the currents in their branches (transmission lines) and voltages in their buses. Compared to other devices, PMUs have the capability of observing other nodes besides the ones they are placed on. Due to a set of observability rules, depending on the plac...

متن کامل

Optimal PMU placement for power system state estimation with random component outages

Phasor measurement unit s (PMUs) provide globally synchronized measurements of voltage and current phasors in real-time and at a high sampling rate. Hence, they permit improving the state estimation performance in power systems. In this paper we propose a novel method for optimal PMU placement in a power system suffering from random component outages (RCOs). In the proposed method, for a given ...

متن کامل

Artificial Bee Colony based Optimal PMU Placement in Power System State Estimation

Advanced power system nowadays demands to ensure accurate estimate of the system states (bus voltages and angles) in order to ensure protection, monitoring, controlling and smooth running of the system. The conventional state estimator estimates the power system states based on the measurements obtained from the Supervisory Control and Data Acquisition (SCADA) system. Besides, the use of synchr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Systems

سال: 2015

ISSN: 0885-8950,1558-0679

DOI: 10.1109/tpwrs.2014.2356797