Optimal Second-Harmonic Current Injection for Capacitor Voltage Fluctuation Reduction in Hybrid MMCs Under Grid-Side SLG Faults
نویسندگان
چکیده
The second-harmonic injection strategy for modular multilevel converters (MMCs) can effectively suppress the capacitor voltage fluctuation in steady states. However, under grid-side single-line-to-ground (SLG) faults will be more severe. Moreover, there is no research on mitigation of SLG hybrid MMC with mixed half-bridge and full-bridge sub-modules. To address this issue MMCs, an optimal current scheme mitigating proposed paper. mathematical models arm power fluctuations are firstly developed both states faults. Then, principle presented. reduced by suppressing three-phase fluctuations. A model has been established PSCAD/EMTDC to verify its effectiveness feasibility. Simulation results show that average reduction rate reach 55.77% strategy.
منابع مشابه
Hybrid Model for Bulk Current Injection Probe
A new hybrid-model for BCI probe is derived . This model is built based on the probe's internal structure without refinements, and by carrying out just one electrical measurement for the reflection coefficient, so that it can be generalized and used in studying the effect of layout parameters in the aim of improving the probe high frequency performance, which helps the developer in design stage...
متن کاملOptimal voltage testing for physically-based faults
In this paper we investigate optimal voltage testing approaches for physically-based faults in CMOS circuits. We describe the general nature of the problem and then focus on two fault types: resistive bridges between gate outputs that cause pattern sensitive functional faults and opens in transmission gates that cause delay faults. In both cases, the traditional stuckat model is inadequate. The...
متن کاملHarmonic Reduction Technique Using Flying Capacitor Based Z Source Inverter for a DVR
The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. The efficiency of the DVR depends on the performance of the efficiency...
متن کاملStability Improvement of Grid-connected Converter with LCL Filter based on Capacitor Current Active Damping by Computational Delay Reduction
Nowadays, LCL filters utilization to suppress the grid-connected inverter switching harmonics is expanding and various methods such as capacitor current active damping scheme could be investigated to damp out these harmonics. However, the computational delays including control system, and PWM switching delays have significant effect on damping system stability. In most of LCL filter parameter d...
متن کاملDesign of a Digital Voltage Controller in Single-Phase Grid-Connected Renewable Converters
Power decoupling of pulsating grid side power from constant source side power is one of the paramount issues in single phase-phase grid-connected renewable systems. The principal aim of such systems is the decrease of the capacitance of the decoupled capacitor. However, this causes some problems such as an increase in the total harmonic distortion (THD) of injected current to the grid and bus v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Power Delivery
سال: 2022
ISSN: ['1937-4208', '0885-8977']
DOI: https://doi.org/10.1109/tpwrd.2021.3118690