A Bremsstrahlung converter for medical apparatuses sterilization has been designed using tantalum and stainless-steel frame a high energy electron accelerator operating at an incident of 7.5 MeV. Optimization the x-ray spectra is investigated in this paper by adding beam hardening filter from copper, aluminum, stainless steel. The MCNP code used to simulate particle transport through design. To survey effect each filtered spectra, angular dose distribution air measured radial distances 50, 75, 100 cm angle 0° 90°. comparison between unfiltered shows marked decrease low photon intensity up keV all three materials with greater reduction when combining materials. These findings result produced having lower closer target due decreased x-rays energy, denoting better homogeneity over irradiated material.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X-ray spectra calculation for different target-filter of mammograms using MCNP Code

 ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...

متن کامل

x-ray spectra calculation for different target-filter of mammograms using mcnp code

abstractbackground: an electron beam generated x-ray spectrum consists of characteristic x-ray and continuous bermsstrahlung. the aim of this research is calculating and comparing x-ray spectra for different target filter of mammograms. materials and methods: monte carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the x-ray spectra. mcn...

متن کامل

X-ray spectra calculation for different target-filter of mammograms using MCNP Code

Mammography is one of the most important imaging techniques to diagnose breast cancer. It is perhaps the single most important innovation in breast cancer control. The importance of mammography is directly related to its value in the early detection and management of breast cancer. Mammography detects approximately 2-3 times as many early breast cancers as physical exams. Breast cancer is the s...

متن کامل

X-ray acoustic computed tomography with pulsed x-ray beam from a medical linear accelerator.

PURPOSE The feasibility of medical imaging using a medical linear accelerator to generate acoustic waves is investigated. This modality, x-ray acoustic computed tomography (XACT), has the potential to enable deeper tissue penetration in tissue than photoacoustic tomography via laser excitation. METHODS Short pulsed (μs-range) 10 MV x-ray beams with dose-rate of approximately 30 Gy∕min were ge...

متن کامل

Measuring the angular dependence of betatron x-ray spectra in a laser-wakefield accelerator

This paper presents a new technique to measure the angular dependence of betatron x-ray spectra in a laser-wakefield accelerator. Measurements are performed with a stacked image plates spectrometer, capable of detecting broadband x-ray radiation up to 1 MeV. It can provide measurements of the betatron x-ray spectrum at any angle of observation (within a 40 mrad cone) and of the beam profile. A ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2022

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2377/1/012047