Organic Charge-Coupled Device

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Charge-coupled device area x-ray detectors

Charge-coupled device ~CCD! area x-ray detector technology is reviewed. CCD detectors consist of a serial chain of signal components, such as phosphors, fiber optics or lenses, image intensifiers and the CCD which serve to convert the x-ray energy to light or electron-hole pairs and to record the spatially resolved image. The various combinations of components that have been used to make CCD de...

متن کامل

Integrating sphere charge coupled device-based measurement method for organic light-emitting devices

An integrating sphere charge coupled device ~CCD!-based measurement system has been developed to accurately characterize the optoelectronic performance of organic polymer light-emitting devices ~PLEDs!. By theoretically analyzing a previously developed lens-coupled method and comparing it with the integrating sphere CCD-based method, we have found that the integrating sphere-based measurement m...

متن کامل

A fast, direct x-ray detection charge-coupled device.

A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 microm thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output po...

متن کامل

Calibration procedures for charge-coupled device x-ray detectors

Calibration procedures are described for use with electronic x-ray detectors, with an emphasis on detectors based on fiber-optically coupled charge-coupled devices. Methods are detailed for removing spurious events, pixel pedestals, dark-current, spatial distortion, and intensity response variations for both small-angle and wide-angle applications. The accuracy of the calibration procedures is ...

متن کامل

Charge-Coupled Device Photometry of Comet P/Halley

Comet P/Halley has been observed during its approach to perihelion at heliocentric distances R = I 1.0 AU and R = 8.2 AU. No extended coma is seen and limits can be placed on the fraction of the total light contributed by coma. The brightness of the comet varies on a short time scale. The variations may be due to transient activity or to rotation of the irregular nucleus. ,. 1984 Academic Pre',...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ACS Photonics

سال: 2019

ISSN: 2330-4022,2330-4022

DOI: 10.1021/acsphotonics.9b00596