Orthogonal Dispersion Spectrometer for Missing Mass Spectra
نویسندگان
چکیده
منابع مشابه
Electric Ion Dispersion as a New Type of Mass Spectrometer
At the 2014 Fields-MPrime Industrial Problem Solving Workshop, PerkinElmer presented a design problem for mass spectrometry. Traditionally mass spectrometry is done via three methods: using magnetic fields to deflect charged particles whereby different masses bend differently; using a time-of-flight procedure where particles of different mass arrive at different times at a target; and using an ...
متن کاملC60 secondary ion mass spectrometry with a hybrid-quadrupole orthogonal time-of-flight mass spectrometer.
A hybrid quadrupole orthogonal time-of-flight mass spectrometer optimized for matrix-assisted laser desorption ionization (MALDI) and electrospray ionization has been equipped with a C 60 cluster ion source. This configuration is shown to exhibit a number of characteristics that improve the performance of traditional time-of-flight secondary ion mass spectrometry (TOF-SIMS) experiments for the ...
متن کاملTemporal dispersion of a spectrometer.
The temporal dispersion of an optical spectrometer has been characterized for a variety of conditions related to optical diagnostics to be fielded at the National Ignition Facility (e.g., full-aperture backscatter station, Thomson scattering). Significant time smear is introduced into these systems by the path length difference through the spectrometer. The temporal resolution is shown to depen...
متن کاملApplication of an orthogonal method for optimizing an inductively coupled plasma mass spectrometer.
The orthogonal method can be used to predict the optimum instrumental conditions and to guide the optimizing operations. This simplifies the ICP-MS optimization. In general, the final optimum parameter combination used in an analysis can be obtained after fine adjustments of the preferred parameters derived from the orthogonal experiment. This method can also be used to study the relationship b...
متن کاملA quadrupole mass spectrometer for resolution of low mass isotopes.
The qualitative and quantitative identification of low mass isotopes in the mass range 1-6 u poses certain difficulties when attempting to achieve the required resolution with an instrument suitable for deployment within a process environment. Certain adjacent species present in the process sample (HT and D(2)) require a resolution greater than 930 to achieve an accurate measurement. We demonst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1965
ISSN: 0018-9499,1558-1578
DOI: 10.1109/tns.1965.4323822