Oscillation Suppression Method by Two Notch Filters for Parallel Inverters under Weak Grid Conditions

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tunable RF Notch Filters for Blocker Suppression

Periodically time-variant passive 8-path notch filters are demonstrated in 65nm CMOS technology, with a notch frequency tunable from 100MHz to 1.2GHz with a clock signal. In a 50Ω environment, filter insertion loss in the pass band is 1.4-2.8dB, while the rejection at the notch frequency is >20dB. Given their P1dB> +2dBm and IIP3> +17dBm, the filters can protect radio receivers from blocking ov...

متن کامل

Resonant Characteristics Analysis and Suppression Strategy of Multiple Parallel Grid-connected Inverters with LCL Filter

The multiple parallel inverters have more than one resonant frequency influenced by many factors, which tends to result in stability and power quality problems. This paper develops the multiple input multiple output model of the grid-connected inverters system using the closed-loop transfer function. The influence factors of resonant characteristics are analyzed with the developed model. The an...

متن کامل

Load Sharing Control of Parallel Inverters with Uncertainty in the Output Filter Impedances for Islanding Operation of AC Micro-Grid

Parallel connection of inverter modules is a solution to increase reliability, efficiency and redundancy of inverters in Micro-Grid system. Proper load sharing among parallel inverters is a key point. The circulating current among the inverters can greatly reduce the efficiency or even cause instability of the system. In this paper, a control strategy for improving the load sharing performance ...

متن کامل

A method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow

Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...

متن کامل

Simplified control method for parallel-connected DC/AC inverters

The parallel operation of several low-capacity inverters is better than a singular highcapacity inverter owing to the advantages of better extensibility and reliability. A simplified control method for parallel-connected inverters is proposed, which can balance the current distribution among the parallel-connected inverters with no interconnected communication lines. To verify the performance o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2018

ISSN: 1996-1073