Output factor determination for dose measurements in axial and perpendicular planes using a silicon strip detector
نویسندگان
چکیده
منابع مشابه
The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry.
PURPOSE Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp ...
متن کاملpassivity in waiting for godot and endgame: a psychoanalytic reading
this study intends to investigate samuel beckett’s waiting for godot and endgame under the lacanian psychoanalysis. it begins by explaining the most important concepts of lacanian psychoanalysis. the beckettian characters are studied regarding their state of unconscious, and not the state of consciousness as is common in most beckett studies. according to lacan, language plays the sole role in ...
Production Phase Database for Star Silicon Strip Detector
The silicon strip detector (SSD) of STAR is a large silicon detector reaching almost half a million channels and made of thousands of components. In order to help in the long production process and store detailed information of the state of the detector a database system has been set up that contains the main characteristics of all the elements of the SSD. This system includes procedures to ent...
متن کاملLow Noise Double - Sided Silicon Strip Detector for Multiple - Compton
A Semiconductor Multiple-Compton Telescope (SMCT) is being developed to explore the gammaray universe in an energy band 0.1–20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of the SMCT is the high energy resolution that is crucial for high angular resolution and high background rejection capability. We have developed prototype modules for a l...
متن کاملSiliSPECT: A Double-Sided Strip Silicon Detector-Based SPECT System
This work describes preliminary test studies with a dual-headed SPECT system that utilizes a new generation of silicon double-sided strip detectors (DSSDs) (Figure 1) with a 1-mm bulk thickness and larger active area (60 × 60 mm) as compared to standard gamma-ray silicon detectors. Furthermore, major improvements in the ASIC design make this detector very suitable for low-energy imaging of smal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review Special Topics - Accelerators and Beams
سال: 2012
ISSN: 1098-4402
DOI: 10.1103/physrevstab.15.042802