P04.05: Measurement of retropubic tissue thickness using intrapartum transperineal ultrasound to assess cephalopelvic disproportion ( CPD)
نویسندگان
چکیده
منابع مشابه
Clinical practice guideline for cesarean section due to cephalopelvic disproportion.
OBJECTIVES To evaluate the effect of the Clinical Practice Guideline (CPG) for cesarean section due to Cephalopelvic Disproportion (CPD) on physician compliance, pregnancy outcomes and cesarean section rate. The study also wants to identify factors associated with physician non-compliance. MATERIAL AND METHOD 455 medical records of women undergoing a cesarean section due to CPD from January 1...
متن کاملRisk factors of caesarean section due to cephalopelvic disproportion.
OBJECTIVE To identify risk factors of cesarean section due to cephalopelvic disproportion SETTING Department of Obstetrics and Gynecology, Faculty of Medicine, Siriraj Hospital. STUDY DESIGN Case-control study. MATERIAL AND METHOD One hundred and three singleton, viable, term pregnant women in cephalic presentation delivered by cesarean section due to cephalopelvic disproportion (CPD) and...
متن کاملSerial intrapartum transperineal ultrasound findings of 59 patients in active phase of labour
Methods Patients in labour are prospectively recruited for the study when cervix was 2cm dilated and or more and completely effaced. Ultrasound scan was performed by single operator using GE Voluson i ultrasound machine. 3D volume was obtained by a single operator. Serial ultrasound scans were performed every 1-2 hours till delivery. The angle of progression and head progression distance were o...
متن کاملMeasurement of infant tongue thickness using ultrasound: a technical note.
Novel uses of ultrasound include obtaining images of intra-oral structures to further research in speech production and feeding. In this technical note we describe a noninvasive, cost-effective, and reliable method for measuring infant tongue muscle thickness. The current pilot study demonstrates high reliability of a trained ultrasonographer to obtain adequate images of the infant tongue and t...
متن کاملUsing ultrasound to assess the thickness of the transversus abdominis in a sling exercise
BACKGROUND Activation of the deep stabilizing trunk muscle transversus abdominis (TrA) is important for trunk stabilization and spine stability. Sling exercises are used for the activation of trunk muscles, therefore we determined the thickness of the TrA in a standardized sling exercise in comparison to rest and abdominal press. Furthermore we propose a standardized measurement method, which c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Ultrasound in Obstetrics & Gynecology
سال: 2017
ISSN: 0960-7692
DOI: 10.1002/uog.18029