P.18 The bupivacaine guessing game: Variance in spinal local anaesthetic volume for preterm caesarean delivery
نویسندگان
چکیده
منابع مشابه
Plain bupivacaine: an unpredictable spinal anaesthetic agent.
Plain bupivacaine 0.5% or 0.75% was injected intrathecally in four groups of 10 patients. Group A received 0.75% bupivacaine 2.7 ml at L3/4, group B 0.5% bupivacaine 4 ml at L3/4, group C 0.75% bupivacaine 2.7 ml at L2/3 and group D 0.75% bupivacaine 2 ml at L3/4. A very wide range of height of block was found in each group and because of this there were few statistically significant difference...
متن کاملEfficacy of low-dose bupivacaine in spinal anaesthesia for Caesarean delivery: systematic review and meta-analysis.
Spinal anaesthesia is the preferred anaesthetic technique for elective Caesarean deliveries. Hypotension is the most common side-effect and has both maternal and neonatal consequences. Different strategies have been attempted to prevent spinal-induced hypotension, including the use of low-dose bupivacaine. We conducted a systematic search for randomized controlled trials comparing the efficacy ...
متن کاملSpinal anaesthesia for caesarean section. The use of 0.5% bupivacaine.
Subarachnoid anaesthesia was induced with 0.5% bupivacaine 2-3.5 ml in 33 women scheduled for elective Caesarean section. Three patients failed to develop adequate analgesia with bupivacaine but were managed satisfactorily with heavy cinchocaine. All the other patients developed adequate analgesia eventually. Since the spread of analgesia was uniquely dependent on posture a new hypothesis is pr...
متن کاملSpinal anaesthesia with 0.25% hyperbaric bupivacaine for caesarean section: effects of volume.
To investigate the safety and efficacy of 0.25% hyperbaric bupivacaine for spinal anaesthesia in Caesarean section, we studied 60 parturients allocated randomly to one of three groups. According to the patient's height, groups 1, 2 and 3 received 3.2-3.6 ml (8-9 mg), 3.6-4.0 ml (9-10 mg) and 4.0-4.4 ml (10-11 mg) of 0.25% bupivacaine in 5% glucose, respectively. Subarachnoid injection was perfo...
متن کاملSpinal anaesthesia for caesarean section: plain vs hyperbaric bupivacaine.
OBJECTIVE To compare the clinical characteristics of sensory and motor block as well as haemodynamic stability using plain and hyperbaric bupivacaine in spinal anaesthesia for caesarean section. METHODS Two equal groups were formed from a total of 60 patients who were enrolled in this prospective randomised double-blinded study that was done at tertiary care hospital in Karach, during 2005 to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Obstetric Anesthesia
سال: 2021
ISSN: 0959-289X
DOI: 10.1016/j.ijoa.2021.103016