Parametric Analysis on Seismic Performance of Hybrid Precast Concrete Beam-Column Joint
نویسندگان
چکیده
منابع مشابه
Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel
Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...
متن کاملDesign of Hybrid Precast Concrete Walls for Seismic Regions
This paper presents an ongoing research project on the behavior and design of “hybrid” precast concrete wall structures for use in seismic regions. Hybrid precast walls utilize a combination of mild (e.g., Grade 60) steel and high-strength unbonded post-tensioning (PT) steel for flexural resistance across horizontal joints. The mild steel reinforcement is designed to yield in tension and compre...
متن کاملSeismic Displacement Demands for Hybrid Precast Concrete Shear Walls
This paper presents an analytical investigation on the peak lateral displacement demands of “hybrid” precast concrete panelized shear wall structures under seismic loading. The hybrid wall structure investigated uses a combination of mild [i.e., Grade 400 (U.S. Grade 60)] steel bars and highstrength unbonded post-tensioning (PT) strands for lateral resistance across horizontal joints. The analy...
متن کاملperformance of exterior precast concrete beam-column dowel connections under cyclic loading
the present study focuses on the performance of precast concrete beam-column dowel connections subjected to cyclic loading by conducting experiments. in this study, one-third scale model of two types of precast and a monolithic beam-column connection were cast and tested under reverse cyclic loading. the precast connections considered for this study is a beam-column connection where beam is con...
متن کاملnon-linear seismic behavior of concrete beam - column connections
a parametrik investigation was conducted to study the non-linear behavior of precast and cast-in-place reinforced concrete beam-column connections subjected to tabas seismic forces (1979). the behavior of these types of connections in a four stories structure with respect to strength, ductility , stiffness, and bond deterioration at the joint core are presented and discussed. calculation result...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Civil Engineering
سال: 2020
ISSN: 1687-8094,1687-8086
DOI: 10.1155/2020/8856327