Partial nephrectomy using microwave tissue coagulator
نویسندگان
چکیده
منابع مشابه
[Non-ischemic partial nephrectomy using microwave tissue coagulator].
PURPOSE The indications and the safety of non-ischemic partial nephrectomy using a microwave tissue coagulator were studied. MATERIALS AND METHODS Non-ischemic partial nephrectomy was performed on 17 kidneys of 16 patients using a microwave tissue coagulator. The diagnosis was renal tumor and renal stones in eleven and five patients, respectively. Renal tumors were less than 4 centimeters in ...
متن کاملTransumbilical laparoendoscopic single-site partial nephrectomy using a microwave tissue coagulator
Transumbilical single-port laparoscopy has emerged as a method to further enhance cosmetic benefits and reduce morbidity. We present an initial experience with transumbilical laparoendoscopic single-site partial nephrectomy (LESS-PN). A 36-year-old woman visited our hospital for the treatment of a left exophytic renal cell carcinoma, 17 mm in diameter, located at the lower pole. We decided to u...
متن کاملLaparoscopic partial nephrectomy using a microwave tissue coagulator for treating small peripheral renal tumors.
BACKGROUND Laparoscopic partial nephrectomy has been recently applied as a minimally invasive procedure. Several non-ischemic operation devices in partial nephrectomy have been developed. However, the problem related to maintenance of renal homeostasis remains. We investigated the efficacy and safety of a microwave tissue coagulator in laparoscopic partial nephrectomy. METHODS Between April 2...
متن کاملHand-assisted, conventional and laparoendoscopic single-site surgery for partial nephrectomy without ischemia using a microwave tissue coagulator.
PURPOSE We report our experience of minimally invasive partial nephrectomy without ischemia using a microwave tissue coagulator (MTC) for hand-assisted laparoscopic partial nephrectomy (HALPN), conventional laparoscopic partial nephrectomy (CLPN), and laparoendoscopic single-site surgery for partial nephrectomy (LESSPN). We retrospectively compared the results of these techniques to better defi...
متن کاملComparison of the loss of renal function after cold ischemia open partial nephrectomy, warm ischemia laparoscopic partial nephrectomy and laparoscopic partial nephrectomy using microwave coagulation.
PURPOSE Nephron sparing surgery is an effective surgical option in patients with renal cell carcinoma. Laparoscopic partial nephrectomy involves clamping and unclamping techniques of the renal vasculature. This study compared the postoperative renal function of partial nephrectomy using an estimation of the glomerular filtration rate (eGFR) for a Japanese population in 3 procedures; open partia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Microwave Surgery
سال: 1995
ISSN: 0917-7728,1882-210X
DOI: 10.3380/jmicrowavesurg.13.17