Patient-related QA for helical TomoTherapy with Delta4: analysis of the results
نویسندگان
چکیده
منابع مشابه
the evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology
abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...
15 صفحه اولQA for helical tomotherapy: report of the AAPM Task Group 148.
Helical tomotherapy is a relatively new modality with integrated treatment planning and delivery hardware for radiation therapy treatments. In view of the uniqueness of the hardware design of the helical tomotherapy unit and its implications in routine quality assurance, the Therapy Physics Committee of the American Association of Physicists in Medicine commissioned Task Group 148 to review thi...
متن کاملEvaluation of a 3D diode array dosimeter for helical tomotherapy delivery QA.
The Delta4 biplanar diode array dosimeter was validated for helical tomotherapy delivery QA. The basic detector characteristics were found to be satisfactory in terms of short-term reproducibility (0.1%), linearity (<0.1%), dose rate dependence (0.4%), and absolute calibration accuracy (0.4% in the center of the phantom compared with the independently calibrated diode). Relative calibration of ...
متن کاملThe helical tomotherapy thread effect.
Inherent to helical tomotherapy is a dose variation pattern that manifests as a "ripple" (peak-to-trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering ...
متن کاملStatistical validation of a new helical tomotherapy patient transfer station
The purpose of this work is to evaluate statistically the accuracy of a patient transfer station (PTS, TomoTherapy Inc., Madison, WI) that automatically converts one planning-station-generated treatment plan to another one with a different beam model. In our department we have installed 2 HI*ART tomotherapy systems, and patients often need to be transferred from one tomotherapy unit to the othe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Current Directions in Biomedical Engineering
سال: 2017
ISSN: 2364-5504
DOI: 10.1515/cdbme-2017-0133