Patient Specific Quality Assurance: Transition from IMRT to IMAT
نویسندگان
چکیده
منابع مشابه
Evaluation of Dosimetry Check software for IMRT patient‐specific quality assurance
The purpose of this study is to evaluate the use of the Dosimetry Check system for patient-specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the patient's CT scans. Instead of making dose co...
متن کاملROC analysis in patient specific quality assurance.
PURPOSE This work investigates the use of receiver operating characteristic (ROC) methods in patient specific IMRT quality assurance (QA) in order to determine unbiased methods to set threshold criteria for γ-distance to agreement measurements. METHODS A group of 17 prostate plans was delivered as planned while a second group of 17 prostate plans was modified with the introduction of random m...
متن کاملQuality Assurance of IMRT delivery systems – Varian
Introduction Intensity modulated radiation therapy (IMRT) provides the means for improved treatment for a wide variety of cancers. Piggybacked onto 3DCRT and MLC technologies, IMRT has developed quickly, but will undoubtedly see improvements in core hardware and software as well as in peripheral applications such as record and verify, gating, etc. At the core, individual treatment centers shoul...
متن کاملClinical implications of the overshoot effect for treatment plan delivery and patient‐specific quality assurance for step‐and‐shoot IMRT
In this work, overshoot and undershoot effects associated with step-and-shoot IMRT (SSIMRT) delivery on a Varian Clinac 21iX are investigated, and their impact on patient-specific QA point dose measurements and treatment plan delivery are evaluated. Pinnacle3 SSIMRT plans consisting of 5, 10, and 15 identical 5 × 5 cm2 MLC defined segments and MU/segment values of 5 MU, 10 MU, and 20 MU were ut...
متن کاملQuality assurance device for four‐dimensional IMRT or SBRT and respiratory gating using patient‐specific intrafraction motion kernels
Emerging technologies such as four-dimensional computed tomography (4D CT) and implanted beacons are expected to allow clinicians to accurately model intrafraction motion and to quantitatively estimate internal target volumes (ITVs) for radiation therapy involving moving targets. In the case of intensity-modulated (IMRT) and stereotactic body radiation therapy (SBRT) delivery, clinicians must c...